Filtered by vendor Philips
Subscribe
Total
107 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2020-16228 | 1 Philips | 24 Intellivue Mp2-mp90, Intellivue Mp2-mp90 Firmware, Intellivue Mx100 and 21 more | 2026-02-23 | 5.2 MEDIUM | 6.4 MEDIUM |
|
In Patient Information Center iX (PICiX) Versions C.02 and C.03,
PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors
MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and
prior, the software does not check or incorrectly checks the revocation
status of a certificate, which may cause it to use a compromised
certificate.
|
|||||
| CVE-2020-16224 | 1 Philips | 1 Patient Information Center Ix | 2026-02-23 | 3.3 LOW | 6.5 MEDIUM |
|
In Patient Information Center iX (PICiX) Versions C.02, C.03, the
software parses a formatted message or structure but does not handle or
incorrectly handles a length field that is inconsistent with the actual
length of the associated data, causing the application on the
surveillance station to restart.
|
|||||
| CVE-2020-16222 | 1 Philips | 2 Patient Information Center Ix, Performancebridge Focal Point | 2026-02-23 | 5.8 MEDIUM | 8.8 HIGH |
|
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and
PerformanceBridge Focal Point Version A.01, when an actor claims to have
a given identity, the software does not prove or insufficiently proves
the claim is correct.
|
|||||
| CVE-2020-16220 | 1 Philips | 2 Patient Information Center Ix, Performancebridge Focal Point | 2026-02-23 | 3.3 LOW | 4.3 MEDIUM |
|
In Patient Information Center iX (PICiX) Versions C.02, C.03,
PerformanceBridge Focal Point Version A.01, the product receives input
that is expected to be well-formed (i.e., to comply with a certain
syntax) but it does not validate or incorrectly validates that the input
complies with the syntax, causing the certificate enrollment service to
crash. It does not impact monitoring but prevents new devices from
enrolling.
|
|||||
| CVE-2020-16218 | 1 Philips | 1 Patient Information Center Ix | 2026-02-23 | 2.7 LOW | 3.5 LOW |
|
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the
software does not neutralize or incorrectly neutralizes
user-controllable input before it is placed in output that is then used
as a webpage and served to other users. Successful exploitation could
lead to unauthorized access to patient data via a read-only web
application.
|
|||||
| CVE-2020-16216 | 1 Philips | 24 Intellivue Mp2-mp90, Intellivue Mp2-mp90 Firmware, Intellivue Mx100 and 21 more | 2026-02-23 | 6.1 MEDIUM | 6.5 MEDIUM |
|
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750,
MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior,
the product receives input or data but does not validate or incorrectly
validates that the input has the properties required to process the data
safely and correctly, which can induce a denial-of-service condition
through a system restart.
|
|||||
| CVE-2020-16214 | 1 Philips | 1 Patient Information Center Ix | 2026-02-23 | 5.8 MEDIUM | 5.0 MEDIUM |
|
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the
software saves user-provided information into a comma-separated value
(CSV) file, but it does not neutralize or incorrectly neutralizes
special elements that could be interpreted as a command when the file is
opened by spreadsheet software.
|
|||||
| CVE-2017-0199 | 2 Microsoft, Philips | 6 Office, Windows 7, Windows Server 2008 and 3 more | 2025-10-22 | 9.3 HIGH | 7.8 HIGH |
|
Microsoft Office 2007 SP3, Microsoft Office 2010 SP2, Microsoft Office 2013 SP1, Microsoft Office 2016, Microsoft Windows Vista SP2, Windows Server 2008 SP2, Windows 7 SP1, Windows 8.1 allow remote attackers to execute arbitrary code via a crafted document, aka "Microsoft Office/WordPad Remote Code Execution Vulnerability w/Windows API."
|
|||||
| CVE-2017-0143 | 3 Microsoft, Philips, Siemens | 28 Server Message Block, Windows 10 1507, Windows 10 1511 and 25 more | 2025-10-22 | 9.3 HIGH | 8.8 HIGH |
|
The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability." This vulnerability is different from those described in CVE-2017-0144, CVE-2017-0145, CVE-2017-0146, and CVE-2017-0148.
|
|||||
| CVE-2025-27955 | 1 Philips | 1 Clinical Collaboration Platform | 2025-06-13 | N/A | 6.5 MEDIUM |
|
Clinical Collaboration Platform 12.2.1.5 has a weak logout system where the session token remains valid after logout and allows a remote attacker to obtain sensitive information and execute arbitrary code.
|
|||||
| CVE-2025-27954 | 1 Philips | 1 Clinical Collaboration Platform | 2025-06-13 | N/A | 6.5 MEDIUM |
|
An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the usertoken function of default.aspx.
|
|||||
| CVE-2025-27953 | 1 Philips | 1 Clinical Collaboration Platform | 2025-06-13 | N/A | 6.5 MEDIUM |
|
An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the session management component.
|
|||||
| CVE-2020-16247 | 1 Philips | 1 Clinical Collaboration Platform | 2025-06-04 | 3.6 LOW | 6.8 MEDIUM |
|
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.
|
|||||
| CVE-2020-16241 | 1 Philips | 2 Suresigns Vs4, Suresigns Vs4 Firmware | 2025-06-04 | 2.1 LOW | 6.3 MEDIUM |
|
Philips SureSigns VS4, A.07.107 and prior
does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
|
|||||
| CVE-2020-16239 | 1 Philips | 2 Suresigns Vs4, Suresigns Vs4 Firmware | 2025-06-04 | 4.0 MEDIUM | 4.9 MEDIUM |
|
When an actor claims to have a given identity,
Philips SureSigns VS4, A.07.107 and prior
does not prove or insufficiently proves the claim is correct.
|
|||||
| CVE-2020-16237 | 1 Philips | 2 Suresigns Vs4, Suresigns Vs4 Firmware | 2025-06-04 | 2.1 LOW | 2.1 LOW |
|
Philips SureSigns VS4, A.07.107 and prior receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
|
|||||
| CVE-2020-16200 | 1 Philips | 1 Clinical Collaboration Platform | 2025-06-04 | 3.3 LOW | 6.5 MEDIUM |
|
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
does not properly control the allocation and maintenance of a limited
resource, thereby enabling an attacker to influence the amount of
resources consumed, eventually leading to the exhaustion of available
resources.
|
|||||
| CVE-2020-16198 | 1 Philips | 1 Clinical Collaboration Platform | 2025-06-04 | 5.8 MEDIUM | 5.0 MEDIUM |
|
When an attacker claims to have a given identity,
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
does not prove or insufficiently proves the claim is correct.
|
|||||
| CVE-2020-14525 | 1 Philips | 1 Clinical Collaboration Platform | 2025-06-04 | 2.7 LOW | 3.5 LOW |
|
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input
before it is placed in output used as a webpage that is served to other
users.
|
|||||
| CVE-2020-14518 | 1 Philips | 1 Dreammapper | 2025-06-04 | 5.0 MEDIUM | 5.3 MEDIUM |
|
Philips DreamMapper, Version 2.24 and prior. Information written to log files can give guidance to a potential attacker.
|
|||||
| CVE-2020-14477 | 1 Philips | 16 Affiniti 50, Affiniti 50 Firmware, Affiniti 70 and 13 more | 2025-06-04 | 3.6 LOW | 3.6 LOW |
|
In Philips Ultrasound ClearVue Versions 3.2 and prior, Ultrasound CX Versions 5.0.2 and prior, Ultrasound EPIQ/Affiniti Versions VM5.0 and prior, Ultrasound Sparq Version 3.0.2 and prior and Ultrasound Xperius all versions, an attacker may use an alternate path or channel that does not require authentication of the alternate service login to view or modify information.
|
|||||
| CVE-2020-12023 | 1 Philips | 1 Intellibridge Enterprise | 2025-06-04 | 2.7 LOW | 2.0 LOW |
|
Philips IntelliBridge Enterprise (IBE), Versions B.12 and prior, IntelliBridge Enterprise system integration with SureSigns (VS4), EarlyVue (VS30) and IntelliVue Guardian (IGS). Unencrypted user credentials received in the IntelliBridge Enterprise (IBE) are logged within the transaction logs, which are secured behind the login based administrative web portal. The unencrypted user credentials sent from the affected products listed above, for the purpose of handshake or authentication with the Ent ...
Show More |
|||||
| CVE-2020-27298 | 1 Philips | 5 Coronary Tools, Dynamic Coronary Roadmap, Interventional Workspot and 2 more | 2025-06-04 | 3.3 LOW | 6.5 MEDIUM |
|
Philips Interventional Workspot (Release 1.3.2, 1.4.0, 1.4.1, 1.4.3, 1.4.5), Coronary Tools/Dynamic Coronary Roadmap/Stentboost Live (Release 1.0), ViewForum (Release 6.3V1L10). The software constructs all or part of an OS command using externally influenced input from an upstream component but does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when sent to a downstream component.
|
|||||
| CVE-2020-14506 | 1 Philips | 1 Clinical Collaboration Platform | 2025-06-04 | 4.3 MEDIUM | 3.4 LOW |
|
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
|
|||||
| CVE-2017-14111 | 1 Philips | 2 Intellispace Cardiovascular, Xcelera | 2025-04-20 | 4.0 MEDIUM | 7.2 HIGH |
|
The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements.
|
|||||
| CVE-2015-2884 | 1 Philips | 1 In.sight B120\\37 | 2025-04-20 | 5.0 MEDIUM | 7.5 HIGH |
|
Philips In.Sight B120/37 allows remote attackers to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi.
|
|||||
| CVE-2015-2882 | 1 Philips | 1 In.sight B120\\37 | 2025-04-20 | 10.0 HIGH | 9.8 CRITICAL |
|
Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account.
|
|||||
| CVE-2017-14797 | 1 Philips | 2 Hue Bridge Bsb002, Hue Bridge Bsb002 Firmware | 2025-04-20 | 7.9 HIGH | 7.5 HIGH |
|
Lack of Transport Encryption in the public API in Philips Hue Bridge BSB002 SW 1707040932 allows remote attackers to read API keys (and consequently bypass the pushlink protection mechanism, and obtain complete control of the connected accessories) by leveraging the ability to sniff HTTP traffic on the local intranet network.
|
|||||
| CVE-2015-2883 | 1 Philips | 1 In.sight B120\\37 | 2025-04-20 | 3.5 LOW | 5.4 MEDIUM |
|
Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php.
|
|||||
| CVE-2021-27497 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2025-04-17 | 7.5 HIGH | 6.5 MEDIUM |
|
Philips Vue PACS versions 12.2.x.x and prior does not use or incorrectly uses a protection mechanism that provides sufficient defense against directed attacks against the product.
|
|||||
| CVE-2021-27493 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2025-04-17 | 6.4 MEDIUM | 6.1 MEDIUM |
|
Philips Vue PACS versions 12.2.x.x and prior does not ensure or incorrectly ensures structured messages or data are well formed and that certain security properties are met before being read from an upstream component or sent to a downstream component.
|
|||||
| CVE-2021-39369 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2025-04-14 | N/A | 6.5 MEDIUM |
|
In Philips (formerly Carestream) Vue MyVue PACS through 12.2.x.x, the VideoStream function allows Path Traversal by authenticated users to access files stored outside of the web root.
|
|||||
| CVE-2013-2808 | 1 Philips | 4 Xper Flex Cardio, Xper Information Management Physiomonitoring 5, Xper Information Management Vascular Monitoring 5 and 1 more | 2025-04-11 | 9.3 HIGH | N/A |
|
Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management Vascular Monitoring 5 components, and Xper Information Management servers and workstations for Flex Cardio products before XperConnect 1.5.4.053 SP2 allows remote attackers to execute arbitrary code via a crafted HTTP request to the Connect broker on TCP port 6000.
|
|||||
| CVE-2023-40704 | 1 Philips | 1 Vue Pacs | 2025-04-09 | N/A | 6.8 MEDIUM |
|
The product does not require unique and complex passwords to be created
during installation. Using Philips's default password could jeopardize
the PACS system if the password was hacked or leaked. An attacker could
gain access to the database impacting system availability and data
integrity.
|
|||||
| CVE-2022-0922 | 1 Philips | 2 E-alert, E-alert Firmware | 2024-11-21 | 5.7 MEDIUM | 6.5 MEDIUM |
|
The software does not perform any authentication for critical system functionality.
|
|||||
| CVE-2021-43552 | 1 Philips | 1 Patient Information Center Ix | 2024-11-21 | 2.1 LOW | 6.1 MEDIUM |
|
The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03.
|
|||||
| CVE-2021-43550 | 1 Philips | 3 Efficia Cm, Efficia Cm Firmware, Patient Information Center Ix | 2024-11-21 | 3.3 LOW | 5.9 MEDIUM |
|
The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0.
|
|||||
| CVE-2021-43548 | 1 Philips | 1 Patient Information Center Ix | 2024-11-21 | 3.3 LOW | 6.5 MEDIUM |
|
Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
|
|||||
| CVE-2021-42744 | 1 Philips | 4 Mri 1.5t, Mri 1.5t Firmware, Mri 3t and 1 more | 2024-11-21 | 2.1 LOW | 6.2 MEDIUM |
|
Philips MRI 1.5T and MRI 3T Version 5.x.x exposes sensitive information to an actor not explicitly authorized to have access.
|
|||||
| CVE-2021-39376 | 1 Philips | 1 Tasy Electronic Medical Record | 2024-11-21 | 6.5 MEDIUM | 8.8 HIGH |
|
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the CorCad_F2/executaConsultaEspecifico IE_CORPO_ASSIST or CD_USUARIO_CONVENIO parameter.
|
|||||