Vulnerabilities (CVE)

Filtered by vendor Medtronic
Angry Yack Logo
Total 29 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2025-12994 1 Medtronic 1 Carelink Network 2025-12-22 N/A 5.3 MEDIUM
Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue affects CareLink Network: before December 4, 2025.
CVE-2025-12995 1 Medtronic 1 Carelink Network 2025-12-22 N/A 8.1 HIGH
Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances. This issue affects CareLink Network: before December 4, 2025.
CVE-2025-12996 1 Medtronic 1 Carelink Network 2025-12-22 N/A 4.1 MEDIUM
Medtronic CareLink Network allows a local attacker with access to log files on an internal API server to view plaintext passwords from errors logged under certain circumstances. This issue affects CareLink Network: before December 4, 2025.
CVE-2025-12997 1 Medtronic 1 Carelink Network 2025-12-22 N/A 2.2 LOW
Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated attacker with access to specific device and user information to submit web requests to an API endpoint that would expose sensitive user information. This issue affects CareLink Network: before December 4, 2025.
CVE-2018-10631 1 Medtronic 4 N\'vision 8840, N\'vision 8840 Firmware, N\'vision 8870 and 1 more 2025-08-26 4.6 MEDIUM 6.3 MEDIUM
The 8840 Clinician Programmer executes the application program from the 8870 Application Card. An attacker with physical access to an 8870 Application Card and sufficient technical capability can modify the contents of this card, including the binary executables. If modified to bypass protection mechanisms, this malicious code will be run when the card is inserted into an 8840 Clinician Programmer.
CVE-2018-8849 1 Medtronic 4 N\'vision 8840, N\'vision 8840 Firmware, N\'vision 8870 and 1 more 2025-06-27 2.1 LOW 4.6 MEDIUM
Medtronic N'Vision Clinician Programmer 8840 N'Vision Clinician Programme and 8870 N'Vision removable Application Card do not encrypt PII and PHI while at rest.
CVE-2020-27252 1 Medtronic 2 Mycarelink Smart Model 25000, Mycarelink Smart Model 25000 Firmware 2025-05-22 9.3 HIGH 8.8 HIGH
Medtronic MyCareLink Smart 25000 is vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to be uploaded and executed on the Patient Reader. If exploited, an attacker could remotely execute code on the MCL Smart Patient Reader device, leading to control of the device.
CVE-2020-25187 1 Medtronic 2 Mycarelink Smart Model 25000, Mycarelink Smart Model 25000 Firmware 2025-05-22 10.0 HIGH 8.8 HIGH
Medtronic MyCareLink Smart 25000 is  vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart Patient Reader software stack. The heap overflow could allow an attacker to remotely execute code on the MCL Smart Patient Reader, potentially leading to control of the device
CVE-2020-25183 1 Medtronic 2 Mycarelink Smart Model 25000, Mycarelink Smart Model 25000 Firmware 2025-05-22 5.8 MEDIUM 8.0 HIGH
Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart pho ...

Show More

CVE-2019-6540 1 Medtronic 46 Amplia Crt-d, Amplia Crt-d Firmware, Carelink 2090 and 43 more 2025-05-22 3.3 LOW 6.5 MEDIUM
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access t ...

Show More

CVE-2019-6538 1 Medtronic 40 Amplia Crt-d, Amplia Crt-d Firmware, Carelink 2090 and 37 more 2025-05-22 3.3 LOW 9.3 CRITICAL
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent ...

Show More

CVE-2019-13543 1 Medtronic 5 Valleylab Exchange Client, Valleylab Ft10 Energy Platform, Valleylab Ft10 Energy Platform Firmware and 2 more 2025-05-22 5.0 MEDIUM 5.8 MEDIUM
Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use multiple sets of hard-coded credentials. If discovered, they can be used to read files on the device.
CVE-2019-13539 1 Medtronic 5 Valleylab Exchange Client, Valleylab Ft10 Energy Platform, Valleylab Ft10 Energy Platform Firmware and 2 more 2025-05-22 7.2 HIGH 7.0 HIGH
Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use the descrypt algorithm for OS password hashing. While interactive, network-based logons are disabled, and attackers can use the other vulnerabilities within this report to obtain local shell access and access these hashes.
CVE-2019-13535 1 Medtronic 4 Valleylab Ft10 Energy Platform, Valleylab Ft10 Energy Platform Firmware, Valleylab Ls10 Energy Platform and 1 more 2025-05-22 2.1 LOW 4.6 MEDIUM
In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the RFID security mechanism does not apply read protection, allowing for full read access of the RFID security mechanism data.
CVE-2019-13531 1 Medtronic 4 Valleylab Ft10 Energy Platform, Valleylab Ft10 Energy Platform Firmware, Valleylab Ls10 Energy Platform and 1 more 2025-05-22 2.1 LOW 4.8 MEDIUM
In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the RFID security mechanism used for authentication between the FT10/LS10 Energy Platform and instruments can be bypassed, allowing for inauthentic instruments to connect to the generator.
CVE-2019-10964 1 Medtronic 38 Minimed 508, Minimed 508 Firmware, Minimed Paradigm 511 and 35 more 2025-05-22 5.8 MEDIUM 7.1 HIGH
Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control ins ...

Show More

CVE-2018-8870 1 Medtronic 4 24950 Mycarelink Monitor, 24950 Mycarelink Monitor Firmware, 24952 Mycarelink Monitor and 1 more 2025-05-22 7.2 HIGH 6.4 MEDIUM
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system.
CVE-2018-8868 1 Medtronic 4 24950 Mycarelink Monitor, 24950 Mycarelink Monitor Firmware, 24952 Mycarelink Monitor and 1 more 2025-05-22 6.9 MEDIUM 6.2 MEDIUM
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit other vulnerabilities to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range ...

Show More

CVE-2018-5448 1 Medtronic 2 2090 Carelink Programmer, 2090 Carelink Programmer Firmware 2025-05-22 2.7 LOW 4.8 MEDIUM
Medtronic 2090 CareLink Programmer’s software deployment network contains a directory traversal vulnerability that could allow an attacker to read files on the system.
CVE-2018-5446 1 Medtronic 2 2090 Carelink Programmer, 2090 Carelink Programmer Firmware 2025-05-22 2.1 LOW 4.9 MEDIUM
Medtronic 2090 CareLink Programmer uses a per-product username and password that is stored in a recoverable format.
CVE-2018-10596 1 Medtronic 2 2090 Carelink Programmer, 2090 Carelink Programmer Firmware 2025-05-22 5.2 MEDIUM 7.1 HIGH
Medtronic 2090 CareLink Programmer uses a virtual private network connection to securely download updates. It does not verify it is still connected to this virtual private network before downloading updates. The affected products initially establish an encapsulated IP-based VPN connection to a Medtronic-hosted update network. Once the VPN is established, it makes a request to a HTTP (non-TLS) server across the VPN for updates, which responds and provides any available updates. The programmer-s ...

Show More

CVE-2018-18984 1 Medtronic 6 29901 Encore Programmer, 29901 Encore Programmer Firmware, Carelink 2090 Programmer and 3 more 2025-05-22 2.1 LOW 4.6 MEDIUM
Medtronic CareLink and Encore Programmers do not encrypt or do not sufficiently encrypt sensitive PII and PHI information while at rest .
CVE-2018-10634 1 Medtronic 18 Minimed 530g Mmt-551, Minimed 530g Mmt-551 Firmware, Minimed 530g Mmt-751 and 15 more 2025-05-22 2.9 LOW 4.8 MEDIUM
Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers.
CVE-2018-10626 1 Medtronic 4 Mycarelink 24950 Patient Monitor, Mycarelink 24950 Patient Monitor Firmware, Mycarelink 24952 Patient Monitor and 1 more 2025-05-22 3.8 LOW 4.4 MEDIUM
Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.
CVE-2018-10622 1 Medtronic 4 Mycarelink 24950 Patient Monitor, Mycarelink 24950 Patient Monitor Firmware, Mycarelink 24952 Patient Monitor and 1 more 2025-05-22 1.9 LOW 4.9 MEDIUM
Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication and encryption of local data at rest.
CVE-2011-3386 1 Medtronic 1 Paradigm Wireless Insulin Pump 2025-04-11 4.0 MEDIUM N/A
Unspecified vulnerability in Medtronic Paradigm wireless insulin pump 512, 522, 712, and 722 allows remote attackers to modify the delivery of an insulin bolus dose and cause a denial of service (adverse human health effects) via unspecified vectors involving wireless communications and knowledge of the device's serial number, as demonstrated by Jerome Radcliffe at the Black Hat USA conference in August 2011. NOTE: the vendor has disputed the severity of this issue, saying "we believe the risk ...

Show More

CVE-2023-31222 1 Medtronic 1 Paceart Optima 2024-11-21 N/A 9.8 CRITICAL
Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration via network connectivity.
CVE-2023-25931 1 Medtronic 2 Interstim X Clinician, Micro Clinician 2024-11-21 N/A 6.4 MEDIUM
Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requires a security update to fix. Not updating could potentially result in unauthorized control of the clinician therapy application, which has greater control over therapy parameters than the patient app. Changes still cannot be made outside of the established therapy parameters of the programmer. For unauthorized access to occur, an indivi ...

Show More

CVE-2022-32537 1 Medtronic 56 Guardian Link 2 Transmitter Mmt-7730, Guardian Link 2 Transmitter Mmt-7730 Firmware, Guardian Link 2 Transmitter Mmt-7731 and 53 more 2024-11-21 N/A 4.8 MEDIUM
A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance