Filtered by vendor Br-automation
Subscribe
Total
41 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2024-5800 | 1 Br-automation | 1 Automation Runtime | 2025-12-19 | N/A | 7.5 HIGH |
|
Diffie-Hellman groups with insufficient strength are used in the SSL/TLS stack of B&R Automation Runtime versions before 6.0.2, allowing a network attacker to decrypt the SSL/TLS communication.
|
|||||
| CVE-2021-22280 | 1 Br-automation | 1 Automation Studio | 2025-12-19 | N/A | 7.2 HIGH |
|
Improper DLL loading algorithms in B&R Automation Studio versions >=4.0 and <4.12 may allow an authenticated local attacker to execute code in the context of the product.
|
|||||
| CVE-2024-0220 | 1 Br-automation | 2 Automation Studio, Technology Guarding | 2025-05-06 | N/A | 8.3 HIGH |
|
B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data.
|
|||||
| CVE-2024-0323 | 1 Br-automation | 1 Automation Runtime | 2024-11-21 | N/A | 9.8 CRITICAL |
|
The FTP server used on the B&R
Automation Runtime supports unsecure encryption mechanisms, such as SSLv3,
TLSv1.0 and TLS1.1. An network-based attacker can exploit the flaws to conduct
man-in-the-middle attacks or to decrypt communications between the affected product
clients.
|
|||||
| CVE-2023-6028 | 1 Br-automation | 1 Automation Runtime | 2024-11-21 | N/A | 6.1 MEDIUM |
|
A reflected
cross-site scripting (XSS) vulnerability exists in the SVG version of System
Diagnostics Manager of B&R Automation Runtime versions <= G4.93 that
enables a remote attacker to execute arbitrary JavaScript code in the context
of the attacked user’s browser session.
|
|||||
| CVE-2023-3242 | 1 Br-automation | 1 Automation Runtime | 2024-11-21 | N/A | 8.6 HIGH |
|
Improper initialization implementation in Portmapper used in B&R Industrial Automation Automation Runtime <G4.93 allows unauthenticated network-based attackers to cause permanent denial-of-service conditions.
|
|||||
| CVE-2023-1617 | 1 Br-automation | 1 Vc4 | 2024-11-21 | N/A | 9.8 CRITICAL |
|
Improper Authentication vulnerability in B&R Industrial Automation B&R VC4 (VNC-Server modules). This vulnerability may allow an unauthenticated network-based attacker to bypass the authentication mechanism of the VC4 visualization on affected devices. The impact of this vulnerability depends on the functionality provided in the visualization.
This issue affects B&R VC4: from 3.* through 3.96.7, from 4.0* through 4.06.7, from 4.1* through 4.16.3, from 4.2* through 4.26.8, from 4.3* through 4.34 ...
Show More |
|||||
| CVE-2022-4286 | 1 Br-automation | 1 Automation Runtime | 2024-11-21 | N/A | 6.1 MEDIUM |
|
A reflected cross-site scripting (XSS) vulnerability exists in System Diagnostics Manager of B&R Automation Runtime versions >=3.00 and <=C4.93 that enables a remote attacker to execute arbitrary JavaScript in the context of the users browser session.
|
|||||
| CVE-2022-43765 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-11-21 | N/A | 7.5 HIGH |
|
B&R APROL versions < R 4.2-07 doesn’t process correctly specially
formatted data packages sent to port 55502/tcp, which may allow a network based
attacker to cause an application Denial-of-Service.
|
|||||
| CVE-2022-43764 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-11-21 | N/A | 9.8 CRITICAL |
|
Insufficient validation of input parameters when
changing configuration on Tbase server in B&R APROL versions < R 4.2-07 could result in buffer
overflow. This may lead to Denial-of-Service conditions or execution of
arbitrary code.
|
|||||
| CVE-2022-43763 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-11-21 | N/A | 7.5 HIGH |
|
Insufficient check of preconditions could lead
to Denial of Service conditions when calling commands on the Tbase server of B&R APROL versions < R 4.2-07.
|
|||||
| CVE-2022-43762 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-11-21 | N/A | 7.5 HIGH |
|
Lack of verification in B&R APROL
Tbase server versions < R 4.2-07 may lead to memory leaks when receiving messages
|
|||||
| CVE-2022-43761 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-11-21 | N/A | 9.4 CRITICAL |
|
Missing authentication when creating and
managing the B&R APROL database in versions < R 4.2-07
allows reading and changing the system configuration.
|
|||||
| CVE-2021-22289 | 1 Br-automation | 1 Studio | 2024-11-21 | N/A | 8.3 HIGH |
|
Improper Input Validation vulnerability in the project upload mechanism in B&R Automation Studio version >=4.0 may allow an unauthenticated network attacker to execute code.
|
|||||
| CVE-2021-22282 | 1 Br-automation | 1 Automation Studio | 2024-11-21 | N/A | 8.3 HIGH |
|
Improper Control of Generation of Code ('Code Injection') vulnerability in B&R Industrial Automation Automation Studio allows Local Execution of Code.This issue affects Automation Studio: from 4.0 through 4.12.
|
|||||
| CVE-2021-22281 | 1 Br-automation | 1 Automation Studio | 2024-11-21 | N/A | 6.3 MEDIUM |
|
: Relative Path Traversal vulnerability in B&R Industrial Automation Automation Studio allows Relative Path Traversal.This issue affects Automation Studio: from 4.0 through 4.12.
|
|||||
| CVE-2021-22275 | 1 Br-automation | 1 Automation Runtime | 2024-11-21 | 7.8 HIGH | 8.6 HIGH |
|
Buffer Overflow vulnerability in B&R Automation Runtime webserver allows an unauthenticated network-based attacker to stop the cyclic program on the device and cause a denial of service.
|
|||||
| CVE-2020-24682 | 2 Br-automation, Microsoft | 3 Automation Net\/pvi, Automation Studio, Windows | 2024-11-21 | N/A | 7.2 HIGH |
|
Unquoted Search Path or Element vulnerability in B&R Industrial Automation Automation Studio, B&R Industrial Automation NET/PVI allows Target Programs with Elevated Privileges.This issue affects Automation Studio: from 4.0 through 4.6, from 4.7.0 before 4.7.7 SP, from 4.8.0 before 4.8.6 SP, from 4.9.0 before 4.9.4 SP; NET/PVI: from 4.0 through 4.6, from 4.7.0 before 4.7.7, from 4.8.0 before 4.8.6, from 4.9.0 before 4.9.4.
|
|||||
| CVE-2020-24681 | 2 Br-automation, Microsoft | 2 Automation Studio, Windows | 2024-11-21 | N/A | 8.2 HIGH |
|
Incorrect Permission Assignment for Critical Resource vulnerability in B&R Industrial Automation Automation Studio allows Privilege Escalation.This issue affects Automation Studio: from 4.6.0 through 4.6.X, from 4.7.0 before 4.7.7 SP, from 4.8.0 before 4.8.6 SP, from 4.9.0 before 4.9.4 SP.
|
|||||
| CVE-2020-11646 | 1 Br-automation | 6 Gatemanager 4260, Gatemanager 4260 Firmware, Gatemanager 8250 and 3 more | 2024-11-21 | 4.0 MEDIUM | 4.3 MEDIUM |
|
A log information disclosure vulnerability in B&R GateManager 4260 and 9250 versions <9.0.20262 and GateManager 8250 versions <9.2.620236042 allows authenticated users to view log information reserved for other users.
|
|||||
| CVE-2020-11645 | 1 Br-automation | 6 Gatemanager 4260, Gatemanager 4260 Firmware, Gatemanager 8250 and 3 more | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
|
A denial of service vulnerability in B&R GateManager 4260 and 9250 versions <9.0.20262 and GateManager 8250 versions <9.2.620236042 allows authenticated users to limit availability of GateManager instances.
|
|||||
| CVE-2020-11644 | 1 Br-automation | 6 Gatemanager 4260, Gatemanager 4260 Firmware, Gatemanager 8250 and 3 more | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
|
The information disclosure vulnerability present in B&R GateManager 4260 and 9250 versions <9.0.20262 and GateManager 8250 versions <9.2.620236042 allows authenticated users to generate fake audit log messages.
|
|||||
| CVE-2020-11643 | 1 Br-automation | 6 Gatemanager 4260, Gatemanager 4260 Firmware, Gatemanager 8250 and 3 more | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
|
An information disclosure vulnerability in B&R GateManager 4260 and 9250 versions <9.0.20262 and GateManager 8250 versions <9.2.620236042 allows authenticated users to view information of devices belonging to foreign domains.
|
|||||
| CVE-2020-11642 | 1 Br-automation | 1 Sitemanager | 2024-11-21 | 4.0 MEDIUM | 7.7 HIGH |
|
The local file inclusion vulnerability present in B&R SiteManager versions <9.2.620236042 allows authenticated users to impact availability of SiteManager instances.
|
|||||
| CVE-2020-11641 | 1 Br-automation | 1 Sitemanager | 2024-11-21 | 4.0 MEDIUM | 7.7 HIGH |
|
A local file inclusion vulnerability in B&R SiteManager versions <9.2.620236042 allows authenticated users to read sensitive files from SiteManager instances.
|
|||||
| CVE-2020-11637 | 1 Br-automation | 1 Automation Runtime | 2024-11-21 | 5.0 MEDIUM | 5.8 MEDIUM |
|
A memory leak in the TFTP service in B&R Automation Runtime versions <N4.26, <N4.34, <F4.45, <E4.53, <D4.63, <A4.73 and prior could allow an unauthenticated attacker with network access to cause a denial of service (DoS) condition.
|
|||||
| CVE-2019-19878 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. An attacker can get access to historical data from AprolSqlServer by bypassing authentication, a different vulnerability than CVE-2019-16358.
|
|||||
| CVE-2019-19877 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
|
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. An attacker can get access to sensitive information outside the working directory via Directory Traversal attacks against AprolSqlServer, a different vulnerability than CVE-2019-16357.
|
|||||
| CVE-2019-19876 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. An EnMon PHP script was vulnerable to SQL injection, a different vulnerability than CVE-2019-10006.
|
|||||
| CVE-2019-19875 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
|
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. Arbitrary commands could be injected (using Python scripts) via the AprolCluster script that is invoked via sudo and thus executes with root privileges, a different vulnerability than CVE-2019-16364.
|
|||||
| CVE-2019-19874 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. Some web scripts in the web interface allowed injection and execution of arbitrary unintended commands on the web server, a different vulnerability than CVE-2019-16364.
|
|||||
| CVE-2019-19873 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. An attacker can get information from the AprolSqlServer DBMS by bypassing authentication, a different vulnerability than CVE-2019-16356 and CVE-2019-9983.
|
|||||
| CVE-2019-19872 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. The AprolLoader could be used to inject and execute arbitrary unintended commands via an unspecified attack scenario, a different vulnerability than CVE-2019-16364.
|
|||||
| CVE-2019-19869 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. PVs could be changed (unencrypted) by using the IosHttp service and the JSON interface.
|
|||||
| CVE-2019-19108 | 1 Br-automation | 2 Automation Runtime, Automation Studio | 2024-11-21 | 7.5 HIGH | 9.4 CRITICAL |
|
An authentication weakness in the SNMP service in B&R Automation Runtime versions 2.96, 3.00, 3.01, 3.06 to 3.10, 4.00 to 4.63, 4.72 and above allows unauthenticated users to modify the configuration of B&R products via SNMP.
|
|||||
| CVE-2019-19102 | 1 Br-automation | 1 Automation Studio | 2024-11-21 | 5.0 MEDIUM | 5.5 MEDIUM |
|
A directory traversal vulnerability in SharpZipLib used in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x and 4.2.x allow unauthenticated users to write to certain local directories. The vulnerability is also known as zip slip.
|
|||||
| CVE-2019-19101 | 1 Br-automation | 1 Automation Studio | 2024-11-21 | 4.3 MEDIUM | 6.5 MEDIUM |
|
A missing secure communication definition and an incomplete TLS validation in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x, 4.2.x, < 4.3.11SP, < 4.4.9SP, < 4.5.5SP, < 4.6.4 and < 4.7.2 enable unauthenticated users to perform MITM attacks via the B&R upgrade server.
|
|||||
| CVE-2019-19100 | 1 Br-automation | 1 Automation Studio | 2024-11-21 | 3.6 LOW | 7.5 HIGH |
|
A privilege escalation vulnerability in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x, 4.2.x, < 4.3.11SP, < 4.4.9SP, < 4.5.4SP, <. 4.6.3SP, < 4.7.2 and < 4.8.1 allow authenticated users to delete arbitrary files via an exposed interface.
|
|||||
| CVE-2024-5624 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-09-13 | N/A | 6.1 MEDIUM |
|
Reflected Cross-Site Scripting (XSS) in Shift Logbook application of B&R APROL <= R 4.4-00P3 may allow a network-based attacker to execute arbitrary JavaScript code in the context of the user's browser session
|
|||||
| CVE-2024-5622 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-09-13 | N/A | 7.8 HIGH |
|
An untrusted search path vulnerability in the AprolConfigureCCServices of B&R APROL <= R 4.2.-07P3 and <= R 4.4-00P3 may allow an authenticated local attacker to execute arbitrary code with elevated privileges.
|
|||||