Vulnerabilities (CVE)

Filtered by vendor Siemens
Angry Yack Logo
Total 2143 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2018-16563 1 Siemens 34 6md85, 6md86, 7ke85 and 31 more 2024-11-21 4.3 MEDIUM 5.9 MEDIUM
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All ve ...

Show More

CVE-2018-16561 1 Siemens 8 Simatic S7-300, Simatic S7-300 Firmware, Simatic S7-300f and 5 more 2024-11-21 7.8 HIGH 7.5 HIGH
A vulnerability has been identified in SIMATIC S7-300 CPUs (All versions < V3.X.16). The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart. Successful exploitation requires an attacker to be able to send a specially crafted S7 communication packet to a communication interface of the CPU. This includes Ethernet, PROFIBUS, and Multi Point Interfaces (MPI). No user interactio ...

Show More

CVE-2018-16559 1 Siemens 2 Simatic S7-1500, Simatic S7-1500 Firmware 2024-11-21 7.8 HIGH 7.5 HIGH
A vulnerability has been identified in SIMATIC S7-1500 CPU (All versions >= V2.0 and < V2.5), SIMATIC S7-1500 CPU (All versions <= V1.8.5). Specially crafted network packets sent to port 80/tcp or 443/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 80/tcp or 443/tcp. Successful exploitation requires no system privileges and no u ...

Show More

CVE-2018-16558 1 Siemens 2 Simatic S7-1500, Simatic S7-1500 Firmware 2024-11-21 7.8 HIGH 7.5 HIGH
A vulnerability has been identified in SIMATIC S7-1500 CPU (All versions >= V2.0 and < V2.5), SIMATIC S7-1500 CPU (All versions <= V1.8.5). Specially crafted network packets sent to port 80/tcp or 443/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 80/tcp or 443/tcp. Successful exploitation requires no system privileges and no u ...

Show More

CVE-2018-16557 1 Siemens 8 Simatic S7-400, Simatic S7-400 Firmware, Simatic S7-400 Pn\/dp V7 and 5 more 2024-11-21 7.8 HIGH 8.2 HIGH
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V ...

Show More

CVE-2018-16556 1 Siemens 10 Simatic S7-400, Simatic S7-400 Firmware, Simatic S7-400 Pn\/dp V7 and 7 more 2024-11-21 7.8 HIGH 7.5 HIGH
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V ...

Show More

CVE-2018-16555 1 Siemens 8 Scalance S602, Scalance S602 Firmware, Scalance S612 and 5 more 2024-11-21 3.5 LOW 5.4 MEDIUM
A vulnerability has been identified in SCALANCE S602 (All versions < V4.0.1.1), SCALANCE S612 (All versions < V4.0.1.1), SCALANCE S623 (All versions < V4.0.1.1), SCALANCE S627-2M (All versions < V4.0.1.1). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At th ...

Show More

CVE-2018-16417 2 Arubanetworks, Siemens 3 Instant, W1750d, W1750d Firmware 2024-11-21 5.0 MEDIUM 7.5 HIGH
Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection.
CVE-2018-13816 1 Siemens 2 Tim 1531 Irc, Tim 1531 Irc Firmware 2024-11-21 7.5 HIGH 10.0 CRITICAL
A vulnerability has been identified in TIM 1531 IRC (All version < V2.0). The devices was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no public exploitation of this vulnerability was known.
CVE-2018-13815 1 Siemens 4 Simatic S7-1200, Simatic S7-1200 Firmware, Simatic S7-1500 and 1 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. The vulnerability, if exploited, could cause a Denial ...

Show More

CVE-2018-13814 1 Siemens 22 Simatic Hmi Comfort Outdoor Panels, Simatic Hmi Comfort Outdoor Panels Firmware, Simatic Hmi Comfort Panels and 19 more 2024-11-21 6.8 MEDIUM 8.8 HIGH
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integr ...

Show More

CVE-2018-13813 1 Siemens 22 Simatic Hmi Comfort Outdoor Panels, Simatic Hmi Comfort Outdoor Panels Firmware, Simatic Hmi Comfort Panels and 19 more 2024-11-21 5.8 MEDIUM 8.1 HIGH
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices ...

Show More

CVE-2018-13812 1 Siemens 22 Simatic Hmi Comfort Outdoor Panels, Simatic Hmi Comfort Outdoor Panels Firmware, Simatic Hmi Comfort Panels and 19 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices ...

Show More

CVE-2018-13811 1 Siemens 1 Simatic Step 7 \(tia Portal\) 2024-11-21 2.1 LOW 5.5 MEDIUM
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1). Password hashes with insufficient computational effort could allow an attacker to access to a project file and reconstruct passwords. The vulnerability could be exploited by an attacker with local access to the project file. No user interaction is required to exploit the vulnerability. The vulnerability could allow the attacker to obtain certain passwords from the project. At the time of advisory publicati ...

Show More

CVE-2018-13810 1 Siemens 4 Cp 1604, Cp 1604 Firmware, Cp 1616 and 1 more 2024-11-21 4.3 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated configuration web server of the affected CP devices could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. At the time of adv ...

Show More

CVE-2018-13809 1 Siemens 4 Cp 1604, Cp 1604 Firmware, Cp 1616 and 1 more 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated web server of the affected CP devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into following a malicious link. User interaction is required for a successful exploitation. At the time of advisory publication no public exploitation of this vulnerability was known.
CVE-2018-13808 1 Siemens 4 Cp 1604, Cp 1604 Firmware, Cp 1616 and 1 more 2024-11-21 6.4 MEDIUM 9.1 CRITICAL
A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). An attacker with network access to port 23/tcp could extract internal communication data or cause a Denial-of-Service condition. Successful exploitation requires network access to a vulnerable device. At the time of advisory publication no public exploitation of this vulnerability was known.
CVE-2018-13807 1 Siemens 6 Scalance X300, Scalance X300 Firmware, Scalance X408 and 3 more 2024-11-21 7.8 HIGH 8.6 HIGH
A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SCALANCE X414 (All versions). The web interface on port 443/tcp could allow an attacker to cause a Denial-of-Service condition by sending specially crafted packets to the web server. The device will automatically reboot, impacting network availability for other devices. An attacker must have network access to port 443/tcp to exploit the vulnerability. Neither valid credentials nor ...

Show More

CVE-2018-13806 1 Siemens 1 Td Keypad Designer 2024-11-21 9.3 HIGH 7.8 HIGH
A vulnerability has been identified in SIEMENS TD Keypad Designer (All versions). A DLL hijacking vulnerability exists in all versions of SIEMENS TD Keypad Designer which could allow an attacker to execute code with the permission of the user running TD Designer. The attacker must have write access to the directory containing the TD project file in order to exploit the vulnerability. A legitimate user with higher privileges than the attacker must open the TD project in order for this vulnerabili ...

Show More

CVE-2018-13805 1 Siemens 6 Simatic Et 200sp, Simatic Et 200sp Firmware, Simatic S7-1500 and 3 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC ET 200SP Open Controller (All versions >= V2.0 and < V2.1.6), SIMATIC S7-1500 Software Controller (All versions >= V2.0 and < V2.5), SIMATIC S7-1500 incl. F (All versions >= V2.0 and < V2.5). An attacker can cause a denial-of-service condition on the network stack by sending a large number of specially crafted packets to the PLC. The PLC will lose its ability to communicate over the network. This vulnerability could be exploited by an attacker with ...

Show More

CVE-2018-13804 1 Siemens 3 Simatic It Line Monitoring System, Simatic It Production Suite, Simatic It Ua Discrete Manufacturing 2024-11-21 9.3 HIGH 8.1 HIGH
A vulnerability has been identified in SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (Versions V7.1 < V7.1 Upd3), SIMATIC IT UA Discrete Manufacturing (Versions < V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.4). An attacker with network access to the installation could bypass the application-level authentication ...

Show More

CVE-2018-13802 1 Siemens 2 Rox Ii, Rox Ii Firmware 2024-11-21 9.0 HIGH 7.2 HIGH
A vulnerability has been identified in ROX II (All versions < V2.12.1). An authenticated attacker with a high-privileged user account access via SSH could circumvent restrictions in place and execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the SSH interface in on port 22/tcp. The attacker must be authenticated to exploit the vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device.
CVE-2018-13801 1 Siemens 2 Rox Ii, Rox Ii Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability has been identified in ROX II (All versions < V2.12.1). An attacker with network access to port 22/tcp and valid low-privileged user credentials for the target device could perform a privilege escalation and gain root privileges. Successful exploitation requires user privileges of a low-privileged user but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system.
CVE-2018-13800 1 Siemens 2 Simatic S7-1200 V4, Simatic S7-1200 V4 Firmware 2024-11-21 4.9 MEDIUM 7.3 HIGH
A vulnerability has been identified in SIMATIC S7-1200 CPU family version 4 (All versions < V4.2.3). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. This ...

Show More

CVE-2018-13799 1 Siemens 1 Simatic Wincc Open Architecture 2024-11-21 6.4 MEDIUM 9.1 CRITICAL
A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions < V3.14-P021). Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could be exploited by an attacker with network access to port 5678/TCP of the SIMATIC WinCC OA V3.14 server. Successful exploitation requires no user privileges and no user interaction. This vulnerability ...

Show More

CVE-2018-13798 1 Siemens 6 Sicam A8000 Cp-8000, Sicam A8000 Cp-8000 Firmware, Sicam A8000 Cp-802x and 3 more 2024-11-21 7.8 HIGH 7.5 HIGH
A vulnerability has been identified in SICAM A8000 CP-8000 (All versions < V14), SICAM A8000 CP-802X (All versions < V14), SICAM A8000 CP-8050 (All versions < V2.00). Specially crafted network packets sent to port 80/TCP or 443/TCP could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the web server. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 80/TCP or 443/TCP. Successful exploitation require ...

Show More

CVE-2018-11466 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). Specially crafted network packets sent to port 102/tcp (ISO-TSAP) could allow a remote attacker to either cause a Denial-of-Service condition of the integrated software firewall or allow to execute code in the context of the software ...

Show More

CVE-2018-11465 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2024-11-21 7.2 HIGH 7.8 HIGH
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could use ioctl calls to do out of bounds reads, arbitrary writes, or execute code in kernel mode. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exp ...

Show More

CVE-2018-11464 1 Siemens 4 Sinumerik 828d, Sinumerik 828d Firmware, Sinumerik 840d Sl and 1 more 2024-11-21 4.3 MEDIUM 3.7 LOW
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The se ...

Show More

CVE-2018-11463 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2024-11-21 4.6 MEDIUM 7.8 HIGH
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Succes ...

Show More

CVE-2018-11462 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). By sending a specially crafted authentication request to the affected systems a remote attacker could escalate his privileges to an elevated user account but not to root. The security vulnerability could be exploited by an attacker wi ...

Show More

CVE-2018-11461 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2024-11-21 4.6 MEDIUM 6.6 MEDIUM
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with user privileges could use the service command application for privilege escalation to an elevated user but not root. The security vulnerability could be exploited by an attacker with local access to the affected ...

Show More

CVE-2018-11460 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2024-11-21 7.2 HIGH 7.8 HIGH
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnera ...

Show More

CVE-2018-11459 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2024-11-21 7.2 HIGH 7.8 HIGH
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could modify a user-writeable configuration file so that after reboot or manual initiation the system reloads the modified configuration file and attacker-controlled code is executed with elevated privileges. The secu ...

Show More

CVE-2018-11458 1 Siemens 6 Sinumerik 828d V4.7, Sinumerik 828d V4.7 Firmware, Sinumerik 840d Sl V4.7 and 3 more 2024-11-21 9.3 HIGH 8.1 HIGH
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually o ...

Show More

CVE-2018-11457 1 Siemens 6 Sinumerik 828d V4.7, Sinumerik 828d V4.7 Firmware, Sinumerik 840d Sl V4.7 and 3 more 2024-11-21 9.3 HIGH 8.1 HIGH
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually o ...

Show More

CVE-2018-11456 1 Siemens 1 Automation License Manager 2024-11-21 5.0 MEDIUM 5.8 MEDIUM
A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4). An attacker with network access to the device could send specially crafted network packets to determine whether or not a network port on another remote system is accessible or not. This allows the attacker to do basic network scanning using the victims machine. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges, no user interaction is requ ...

Show More

CVE-2018-11455 1 Siemens 1 Automation License Manager 2024-11-21 6.8 MEDIUM 8.8 HIGH
A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4), Automation License Manager 6 (All versions < 6.0.1). A directory traversal vulnerability could allow a remote attacker to move arbitrary files, which can result in code execution, compromising confidentiality, integrity and availability of the system. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges or special conditions of the system, b ...

Show More

CVE-2018-11454 1 Siemens 2 Simatic Step 7 \(tia Portal\), Simatic Wincc \(tia Portal\) 2024-11-21 4.4 MEDIUM 8.6 HIGH
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system a ...

Show More

CVE-2018-11453 1 Siemens 2 Simatic Step 7 \(tia Portal\), Simatic Wincc \(tia Portal\) 2024-11-21 4.6 MEDIUM 7.8 HIGH
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system a ...

Show More