Filtered by vendor Siemens
Subscribe
Total
2143 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2018-4860 | 1 Siemens | 2 Scalance M875, Scalance M875 Firmware | 2024-11-21 | 9.0 HIGH | 7.2 HIGH |
|
A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device. At the time of advisory publica ...
Show More |
|||||
| CVE-2018-4859 | 1 Siemens | 2 Scalance M875, Scalance M875 Firmware | 2024-11-21 | 9.0 HIGH | 7.2 HIGH |
|
A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device. At the time of advisory publica ...
Show More |
|||||
| CVE-2018-4858 | 1 Siemens | 11 Digsi 4, Digsi 4 Firmware, Digsi 5 and 8 more | 2024-11-21 | 9.3 HIGH | 7.8 HIGH |
|
A vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions < V7.80), DIGSI 4 (All versions < V4.93), SICAM PAS/PQS (All versions < V8.11), SICAM PQ Analyzer (All versions < V3.11), SICAM SCC (All versions < V9.02 HF3). A service of the affected products listening on all of the host's network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to e ...
Show More |
|||||
| CVE-2018-4856 | 1 Siemens | 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more | 2024-11-21 | 4.0 MEDIUM | 4.9 MEDIUM |
|
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with administrative access to the device's management interface could lock out legitimate users. Manual interaction is required to restore the access of legitimate users.
|
|||||
| CVE-2018-4855 | 1 Siemens | 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more | 2024-11-21 | 4.3 MEDIUM | 6.5 MEDIUM |
|
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). Unencrypted storage of passwords in the client configuration files and during network transmission could allow an attacker in a privileged position to obtain access passwords.
|
|||||
| CVE-2018-4854 | 1 Siemens | 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more | 2024-11-21 | 9.3 HIGH | 8.8 HIGH |
|
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the administrative client stored on the device. If a legitimate user downloads and executes the modified client from the affected device, then he/she could obtain code execution on the client system.
|
|||||
| CVE-2018-4853 | 1 Siemens | 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
|
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the firmware of the device.
|
|||||
| CVE-2018-4852 | 1 Siemens | 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could potentially circumvent the authentication mechanism if he/she is able to obtain certain knowledge specific to the attacked device.
|
|||||
| CVE-2018-4851 | 1 Siemens | 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more | 2024-11-21 | 8.5 HIGH | 8.2 HIGH |
|
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could cause a Denial-of-Service condition by sending certain packets to the device, causing potential reboots of the device. The core functionality of the device could be impacted. The time serving functionality recovers when time synchronization with GPS devices or other NTP servers are completed.
|
|||||
| CVE-2018-4850 | 1 Siemens | 4 Simatic S7-400, Simatic S7-400 Firmware, Simatic S7-400h and 1 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A vulnerability has been identified in SIMATIC S7-400 (incl. F) CPU hardware version 4.0 and below (All versions), SIMATIC S7-400 (incl. F) CPU hardware version 5.0 (All firmware versions < V5.2), SIMATIC S7-400H CPU hardware version 4.5 and below (All versions). The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart.
|
|||||
| CVE-2018-4849 | 1 Siemens | 1 Siveillance Vms Video | 2024-11-21 | 5.8 MEDIUM | 7.4 HIGH |
|
A vulnerability has been identified in Siveillance VMS Video for Android (All versions < V12.1a (2018 R1)), Siveillance VMS Video for iOS (All versions < V12.1a (2018 R1)). Improper certificate validation could allow an attacker in a privileged network position to read data from and write data to the encrypted communication channel between the app and a server. The security vulnerability could be exploited by an attacker in a privileged network position which allows intercepting the communicatio ...
Show More |
|||||
| CVE-2018-4848 | 1 Siemens | 6 Scalance X-200, Scalance X-200 Firmware, Scalance X-200 Irt and 3 more | 2024-11-21 | 4.3 MEDIUM | 6.1 MEDIUM |
|
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked i ...
Show More |
|||||
| CVE-2018-4847 | 1 Siemens | 1 Simatic Wincc Oa Operator | 2024-11-21 | 2.1 LOW | 4.6 MEDIUM |
|
A vulnerability has been identified in SIMATIC WinCC OA Operator iOS App (All versions < V1.4). Insufficient protection of sensitive information (e.g. session key for accessing server) in Siemens WinCC OA Operator iOS app could allow an attacker with physical access to the mobile device to read unencrypted data from the app's directory. Siemens provides mitigations to resolve the security issue.
|
|||||
| CVE-2018-4846 | 1 Siemens | 6 Rapidlab 1200, Rapidlab 1200 Firmware, Rapidpoint 400 and 3 more | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
|
A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 ...
Show More |
|||||
| CVE-2018-4845 | 1 Siemens | 6 Rapidlab 1200, Rapidlab 1200 Firmware, Rapidpoint 400 and 3 more | 2024-11-21 | 6.5 MEDIUM | 8.8 HIGH |
|
A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 ...
Show More |
|||||
| CVE-2018-4844 | 1 Siemens | 1 Simatic Wincc Oa Ui | 2024-11-21 | 3.8 LOW | 6.7 MEDIUM |
|
A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacke ...
Show More |
|||||
| CVE-2018-4843 | 1 Siemens | 22 Simatic Cp 343-1, Simatic Cp 343-1 Firmware, Simatic Cp 443-1 and 19 more | 2024-11-21 | 6.1 MEDIUM | 6.5 MEDIUM |
|
A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 ...
Show More |
|||||
| CVE-2018-4842 | 1 Siemens | 6 Scalance X200, Scalance X200 Firmware, Scalance X200 Irt and 3 more | 2024-11-21 | 3.5 LOW | 4.8 MEDIUM |
|
A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visi ...
Show More |
|||||
| CVE-2018-4841 | 1 Siemens | 2 Tim 1531 Irc, Tim 1531 Irc Firmware | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
|
A vulnerability has been identified in TIM 1531 IRC (All versions < V1.1). A remote attacker with network access to port 80/tcp or port 443/tcp could perform administrative operations on the device without prior authentication. Successful exploitation could allow to cause a denial-of-service, or read and manipulate data as well as configuration settings of the affected device. At the stage of publishing this security advisory no public exploitation is known. Siemens provides mitigations to resol ...
Show More |
|||||
| CVE-2018-4840 | 1 Siemens | 17 Digsi 4, En100 Ethernet Module Dnp3, En100 Ethernet Module Dnp3 Firmware and 14 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access au ...
Show More |
|||||
| CVE-2018-4839 | 1 Siemens | 17 Digsi 4, En100 Ethernet Module Dnp3, En100 Ethernet Module Dnp3 Firmware and 14 more | 2024-11-21 | 3.5 LOW | 5.3 MEDIUM |
|
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions < V4.70), SIPROTE ...
Show More |
|||||
| CVE-2018-4838 | 1 Siemens | 10 En100 Ethernet Module Dnp3, En100 Ethernet Module Dnp3 Firmware, En100 Ethernet Module Iec 104 and 7 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions wit ...
Show More |
|||||
| CVE-2018-4837 | 1 Siemens | 1 Telecontrol Server Basic | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with access to the TeleControl Server Basic's webserver (port 80/tcp or 443/tcp) could cause a Denial-of-Service condition on the web server. The remaining functionality of the TeleControl Server Basic is not affected by the Denial-of-Service condition.
|
|||||
| CVE-2018-4836 | 1 Siemens | 1 Telecontrol Server Basic | 2024-11-21 | 6.5 MEDIUM | 8.8 HIGH |
|
A vulnerability has been identified in TeleControl Server Basic < V3.1. An authenticated attacker with a low-privileged account to the TeleControl Server Basic's port 8000/tcp could escalate his privileges and perform administrative operations.
|
|||||
| CVE-2018-4835 | 1 Siemens | 1 Telecontrol Server Basic | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
|
A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with network access to the TeleControl Server Basic's port 8000/tcp could bypass the authentication mechanism and read limited information.
|
|||||
| CVE-2018-4834 | 1 Siemens | 10 Pxc001-e.d, Pxc001-e.d Firmware, Pxc00\/50\/100\/200-e.d and 7 more | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
|
A vulnerability has been identified in Desigo PXC00-E.D V4.10 (All versions < V4.10.111), Desigo PXC00-E.D V5.00 (All versions < V5.0.171), Desigo PXC00-E.D V5.10 (All versions < V5.10.69), Desigo PXC00-E.D V6.00 (All versions < V6.0.204), Desigo PXC00/64/128-U V4.10 (All versions < V4.10.111 only with web module), Desigo PXC00/64/128-U V5.00 (All versions < V5.0.171 only with web module), Desigo PXC00/64/128-U V5.10 (All versions < V5.10.69 only with web module), Desigo PXC00/64/128-U V6.00 (Al ...
Show More |
|||||
| CVE-2018-4833 | 1 Siemens | 18 Rfid 181-eip, Rfid 181-eip Firmware, Ruggedcom Wimax and 15 more | 2024-11-21 | 5.8 MEDIUM | 8.8 HIGH |
|
A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X408 (All versions < V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C ...
Show More |
|||||
| CVE-2018-4832 | 1 Siemens | 9 Openpcs 7, Simatic Batch, Simatic Net Pc and 6 more | 2024-11-21 | 4.3 MEDIUM | 7.5 HIGH |
|
A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V ...
Show More |
|||||
| CVE-2018-3991 | 3 Microsoft, Siemens, Wibu | 3 Windows, Simatic Wincc Open Architecture, Wibukey | 2024-11-21 | 7.5 HIGH | 10.0 CRITICAL |
|
An exploitable heap overflow vulnerability exists in the WkbProgramLow function of WibuKey Network server management, version 6.40.2402.500. A specially crafted TCP packet can cause a heap overflow, potentially leading to remote code execution. An attacker can send a malformed TCP packet to trigger this vulnerability.
|
|||||
| CVE-2018-3658 | 2 Intel, Siemens | 25 Active Management Technology Firmware, Converged Security Management Engine Firmware, Manageability Engine Firmware and 22 more | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
|
Multiple memory leaks in Intel AMT in Intel CSME firmware versions before 12.0.5 may allow an unauthenticated user with Intel AMT provisioned to potentially cause a partial denial of service via network access.
|
|||||
| CVE-2018-3657 | 2 Intel, Siemens | 25 Active Management Technology Firmware, Converged Security Management Engine Firmware, Manageability Engine Firmware and 22 more | 2024-11-21 | 7.2 HIGH | 6.7 MEDIUM |
|
Multiple buffer overflows in Intel AMT in Intel CSME firmware versions before version 12.0.5 may allow a privileged user to potentially execute arbitrary code with Intel AMT execution privilege via local access.
|
|||||
| CVE-2018-3639 | 12 Arm, Canonical, Debian and 9 more | 321 Cortex-a, Ubuntu Linux, Debian Linux and 318 more | 2024-11-21 | 2.1 LOW | 5.5 MEDIUM |
|
Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis, aka Speculative Store Bypass (SSB), Variant 4.
|
|||||
| CVE-2018-3616 | 2 Intel, Siemens | 25 Active Management Technology Firmware, Converged Security Management Engine Firmware, Manageability Engine Firmware and 22 more | 2024-11-21 | 4.3 MEDIUM | 5.9 MEDIUM |
|
Bleichenbacher-style side channel vulnerability in TLS implementation in Intel Active Management Technology before 12.0.5 may allow an unauthenticated user to potentially obtain the TLS session key via the network.
|
|||||
| CVE-2018-21247 | 5 Canonical, Debian, Libvnc Project and 2 more | 16 Ubuntu Linux, Debian Linux, Libvncserver and 13 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
An issue was discovered in LibVNCServer before 0.9.13. There is an information leak (of uninitialized memory contents) in the libvncclient/rfbproto.c ConnectToRFBRepeater function.
|
|||||
| CVE-2018-20750 | 4 Canonical, Debian, Libvnc Project and 1 more | 15 Ubuntu Linux, Debian Linux, Libvncserver and 12 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
LibVNC through 0.9.12 contains a heap out-of-bounds write vulnerability in libvncserver/rfbserver.c. The fix for CVE-2018-15127 was incomplete.
|
|||||
| CVE-2018-20749 | 4 Canonical, Debian, Libvnc Project and 1 more | 15 Ubuntu Linux, Debian Linux, Libvncserver and 12 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
LibVNC before 0.9.12 contains a heap out-of-bounds write vulnerability in libvncserver/rfbserver.c. The fix for CVE-2018-15127 was incomplete.
|
|||||
| CVE-2018-20748 | 4 Canonical, Debian, Libvnc Project and 1 more | 15 Ubuntu Linux, Debian Linux, Libvncserver and 12 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
LibVNC before 0.9.12 contains multiple heap out-of-bounds write vulnerabilities in libvncclient/rfbproto.c. The fix for CVE-2018-20019 was incomplete.
|
|||||
| CVE-2018-20019 | 4 Canonical, Debian, Libvnc Project and 1 more | 15 Ubuntu Linux, Debian Linux, Libvncserver and 12 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
LibVNC before commit a83439b9fbe0f03c48eb94ed05729cb016f8b72f contains multiple heap out-of-bound write vulnerabilities in VNC client code that can result remote code execution
|
|||||
| CVE-2018-18508 | 2 Mozilla, Siemens | 17 Network Security Services, Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000 Firmware and 14 more | 2024-11-21 | 4.3 MEDIUM | 6.5 MEDIUM |
|
In Network Security Services (NSS) before 3.36.7 and before 3.41.1, a malformed signature can cause a crash due to a null dereference, resulting in a Denial of Service.
|
|||||
| CVE-2018-16890 | 8 Canonical, Debian, F5 and 5 more | 10 Ubuntu Linux, Debian Linux, Big-ip Access Policy Manager and 7 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
libcurl versions from 7.36.0 to before 7.64.0 is vulnerable to a heap buffer out-of-bounds read. The function handling incoming NTLM type-2 messages (`lib/vauth/ntlm.c:ntlm_decode_type2_target`) does not validate incoming data correctly and is subject to an integer overflow vulnerability. Using that overflow, a malicious or broken NTLM server could trick libcurl to accept a bad length + offset combination that would lead to a buffer read out-of-bounds.
|
|||||