Vulnerabilities (CVE)

Filtered by vendor Mitsubishielectric
Angry Yack Logo
Total 158 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2020-5596 1 Mitsubishielectric 4 Coreos, Got2000 Gt23, Got2000 Gt25 and 1 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) does not properly manage sessions, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
CVE-2020-5595 1 Mitsubishielectric 4 Coreos, Got2000 Gt23, Got2000 Gt25 and 1 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains a buffer overflow vulnerability, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
CVE-2020-5594 1 Mitsubishielectric 10 Melsec-fx, Melsec-fx Firmware, Melsec-l and 7 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors.
CVE-2020-5547 1 Mitsubishielectric 2 Iu1-1m20-d, Iu1-1m20-d Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
Resource Management Errors vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
CVE-2020-5546 1 Mitsubishielectric 2 Iu1-1m20-d, Iu1-1m20-d Firmware 2024-11-21 5.8 MEDIUM 8.8 HIGH
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows an attacker on the same network segment to stop the network functions or execute malware via a specially crafted packet.
CVE-2020-5545 1 Mitsubishielectric 2 Iu1-1m20-d, Iu1-1m20-d Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to bypass access restriction and to stop the network functions or execute malware via a specially crafted packet.
CVE-2020-5544 1 Mitsubishielectric 2 Iu1-1m20-d, Iu1-1m20-d Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
Null Pointer Dereference vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
CVE-2020-5543 1 Mitsubishielectric 2 Iu1-1m20-d, Iu1-1m20-d Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier does not properly manage sessions, which allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
CVE-2020-5542 1 Mitsubishielectric 2 Iu1-1m20-d, Iu1-1m20-d Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
Buffer error vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
CVE-2020-5531 1 Mitsubishielectric 10 Mi5122-vw, Mi5122-vw Firmware, Q24dhccpu-v and 7 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): ...

Show More

CVE-2020-5527 1 Mitsubishielectric 92 Cr800-q, Cr800-q Firmware, Fx3g and 89 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
When MELSOFT transmission port (UDP/IP) of Mitsubishi Electric MELSEC iQ-R series (all versions), MELSEC iQ-F series (all versions), MELSEC Q series (all versions), MELSEC L series (all versions), and MELSEC F series (all versions) receives massive amount of data via unspecified vectors, resource consumption occurs and the port does not process the data properly. As a result, it may fall into a denial-of-service (DoS) condition. The vendor states this vulnerability only affects Ethernet communic ...

Show More

CVE-2020-16850 1 Mitsubishielectric 38 R00cpu, R00cpu Firmware, R01cpu and 35 more 2024-11-21 7.8 HIGH 7.5 HIGH
Mitsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. This denial of service attack exposes Improper Input Validation. After halting, physical access to the PLC is required in order to restore production, and the device state is lost. This is related to R04CPU, RJ71GF11-T2, R04CPU, and RJ71GF11-T2.
CVE-2020-16226 1 Mitsubishielectric 186 Conveyor Tracking Application Apr-ntr12fh, Conveyor Tracking Application Apr-ntr20fh\(n\=1\,2\), Conveyor Tracking Application Apr-ntr3fh and 183 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands.
CVE-2020-14523 1 Mitsubishielectric 27 Cw Configurator, Fr Configurator2, Gx Works2 and 24 more 2024-11-21 7.5 HIGH 8.3 HIGH
Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.
CVE-2020-14521 1 Mitsubishielectric 60 C Controller Interface Module Utility, C Controller Module Setting And Monitoring Tool, Cc-link Ie Control Network Data Collector and 57 more 2024-11-21 7.5 HIGH 8.3 HIGH
Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition.
CVE-2020-14496 1 Mitsubishielectric 29 Cpu Module Logging Configuration Tool, Cw Configurator, Data Transfer and 26 more 2024-11-21 7.5 HIGH 8.3 HIGH
Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed.
CVE-2020-13238 1 Mitsubishielectric 42 Melsec Iq-r00cpu, Melsec Iq-r00cpu Firmware, Melsec Iq-r01cpu and 39 more 2024-11-21 7.8 HIGH 7.5 HIGH
Mitsubishi MELSEC iQ-R Series PLCs with firmware 33 allow attackers to halt the industrial process by sending an unauthenticated crafted packet over the network, because this denial of service attack consumes excessive CPU time. After halting, physical access to the PLC is required in order to restore production.
CVE-2020-12015 2 Iconics, Mitsubishielectric 11 Bizviz, Energy Analytix, Facility Analytix and 8 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition due to improper deserialization. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior.
CVE-2020-12013 2 Iconics, Mitsubishielectric 11 Bizviz, Energy Analytix, Facility Analytix and 8 more 2024-11-21 6.4 MEDIUM 9.1 CRITICAL
A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior.
CVE-2020-12011 2 Iconics, Mitsubishielectric 11 Bizviz, Energy Analytix, Facility Analytix and 8 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition or allow remote code execution. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; GenBroker32 version 9.5 and prior.
CVE-2020-12009 2 Iconics, Mitsubishielectric 11 Bizviz, Energy Analytix, Facility Analytix and 8 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior.
CVE-2020-12007 2 Iconics, Mitsubishielectric 11 Bizviz, Energy Analytix, Facility Analytix and 8 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior.
CVE-2019-14931 2 Inea, Mitsubishielectric 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more 2024-11-21 10.0 HIGH 9.8 CRITICAL
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to the RTU's system shell. Functionality in mobile.php provides users with the ability to ping sites or IP addresses via Mobile Connection Test. When the Mobile Connection Test is submitted, action.php is ca ...

Show More

CVE-2019-14930 2 Inea, Mitsubishielectric 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more 2024-11-21 10.0 HIGH 9.8 CRITICAL
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. (Also, the accounts ineaadmin and mitsadmin are able to escalate privileges to root without supplying a password due to insecure entries in /etc/sudoers on the RTU.)
CVE-2019-14929 2 Inea, Mitsubishielectric 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more 2024-11-21 5.0 MEDIUM 9.8 CRITICAL
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak credentials management on the RTU. An unauthenticated user can obtain the exposed password credentials to gain access to the following services: DDNS service, Mobile Network Provider, and OpenVPN service.
CVE-2019-14928 2 Inea, Mitsubishielectric 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more 2024-11-21 3.5 LOW 5.4 MEDIUM
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script (XSS) vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to stored XSS is SerialInitialModemString in the index.php page.
CVE-2019-14927 2 Inea, Mitsubishielectric 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).
CVE-2019-14926 2 Inea, Mitsubishielectric 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with firmware updates. In other words, these devices use private-key values in /etc/ssh/ssh_host_rsa_key, /etc/ssh/ssh_host_ecdsa_key, and /etc/ssh/ssh_host_dsa_key files that are publicly available from the ...

Show More

CVE-2019-14925 2 Inea, Mitsubishielectric 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more 2024-11-21 4.0 MEDIUM 6.5 MEDIUM
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and other sensitive RTU data due to insecure permission assignment.
CVE-2019-13555 1 Mitsubishielectric 20 L02\/06\/26cpu, L02\/06\/26cpu-cm, L02\/06\/26cpu-cm Firmware and 17 more 2024-11-21 4.3 MEDIUM 5.9 MEDIUM
In Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU: serial number 21081 and prior, Q04/06/13/26UDPVCPU: serial number 21081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 21081 and prior, MELSEC-L Series L02/06/26CPU, L26CPU-BT: serial number 21101 and prior, L02/06/26CPU-P, L26CPU-PBT: serial number 21101 and prior, and L02/06/26CPU-CM, L26CPU-BT-CM: serial number 21101 and prior, a remote attacker can cause the FTP service to enter a denial-of-service condi ...

Show More

CVE-2019-10977 1 Mitsubishielectric 2 Qj71e71-100, Qj71e71-100 Firmware 2024-11-21 7.8 HIGH 7.5 HIGH
In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and cause a denial-of-service condition.
CVE-2019-10976 1 Mitsubishielectric 2 Electric Fr Configurator2, Electric Fr Configurator2 Firmware 2024-11-21 4.3 MEDIUM 5.5 MEDIUM
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the XML project and/or template file (.frc2). Once a user opens the file, the attacker could read arbitrary files.
CVE-2019-10972 1 Mitsubishielectric 1 Electric Fr Configurator2 2024-11-21 7.1 HIGH 5.5 MEDIUM
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application is restarted.
CVE-2018-16061 1 Mitsubishielectric 2 Smartrtu, Smartrtu Firmware 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
Mitsubishi Electric Europe B.V. SmartRTU devices allow XSS via the username parameter or PATH_INFO to login.php.
CVE-2018-16060 1 Mitsubishielectric 2 Smartrtu, Smartrtu Firmware 2024-11-21 5.0 MEDIUM 7.5 HIGH
Mitsubishi Electric Europe B.V. SmartRTU devices allow remote attackers to obtain sensitive information (directory listing and source code) via a direct request to the /web URI.
CVE-2017-9638 1 Mitsubishielectric 1 E-designer 2024-11-21 10.0 HIGH 9.8 CRITICAL
Mitsubishi E-Designer, Version 7.52 Build 344 contains six code sections which may be exploited to overwrite the stack. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.
CVE-2017-9636 1 Mitsubishielectric 1 E-designer 2024-11-21 10.0 HIGH 9.8 CRITICAL
Mitsubishi E-Designer, Version 7.52 Build 344 contains five code sections which may be exploited to overwrite the heap. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.
CVE-2017-9634 1 Mitsubishielectric 1 E-designer 2024-11-21 10.0 HIGH 9.8 CRITICAL
Mitsubishi E-Designer, Version 7.52 Build 344 contains two code sections which may be exploited to allow an attacker to overwrite arbitrary memory locations. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.