CVE-2020-16850

M

itsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. This denial of service attack exposes Improper Input Validation. After halting, physical access to the PLC is required in order to restore production, and the device state is lost. This is related to R04CPU, RJ71GF11-T2, R04CPU, and RJ71GF11-T2.

Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:mitsubishielectric:r00cpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r00cpu:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:mitsubishielectric:r01cpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r01cpu:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:mitsubishielectric:r02cpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r02cpu:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:mitsubishielectric:r04cpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r04cpu:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:mitsubishielectric:r08cpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r08cpu:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:mitsubishielectric:r16cpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r16cpu:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:mitsubishielectric:r32cpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r32cpu:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:mitsubishielectric:r120cpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r120cpu:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:mitsubishielectric:r08sfcpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r08sfcpu:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:mitsubishielectric:r16sfcpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r16sfcpu:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:mitsubishielectric:r32sfcpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r32sfcpu:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:mitsubishielectric:r120sfcpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r120sfcpu:-:*:*:*:*:*:*:*

Configuration 13 (hide)

AND
cpe:2.3:o:mitsubishielectric:r08pcpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r08pcpu:-:*:*:*:*:*:*:*

Configuration 14 (hide)

AND
cpe:2.3:o:mitsubishielectric:r16pcpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r16pcpu:-:*:*:*:*:*:*:*

Configuration 15 (hide)

AND
cpe:2.3:o:mitsubishielectric:r32pcpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r32pcpu:-:*:*:*:*:*:*:*

Configuration 16 (hide)

AND
cpe:2.3:o:mitsubishielectric:r120pcpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r120pcpu:-:*:*:*:*:*:*:*

Configuration 17 (hide)

AND
cpe:2.3:o:mitsubishielectric:r16mtcpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r16mtcpu:-:*:*:*:*:*:*:*

Configuration 18 (hide)

AND
cpe:2.3:o:mitsubishielectric:r32mtcpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r32mtcpu:-:*:*:*:*:*:*:*

Configuration 19 (hide)

AND
cpe:2.3:o:mitsubishielectric:r64mtcpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mitsubishielectric:r64mtcpu:-:*:*:*:*:*:*:*

History

21 Nov 2024, 05:07

Type Values Removed Values Added
References () https://blog.scadafence.com/vulnerability-in-mitsubishi-electric-melsec-iq-r-series - Third Party Advisory () https://blog.scadafence.com/vulnerability-in-mitsubishi-electric-melsec-iq-r-series - Third Party Advisory
References () https://us-cert.cisa.gov/ics/advisories/icsa-20-282-02 - Third Party Advisory, US Government Resource () https://us-cert.cisa.gov/ics/advisories/icsa-20-282-02 - Third Party Advisory, US Government Resource