Filtered by vendor Schneider-electric
Subscribe
Total
759 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2020-7480 | 1 Schneider-electric | 22 Andover Continuum 5720, Andover Continuum 5720 Firmware, Andover Continuum 5740 and 19 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application's processing of XML data.
|
|||||
| CVE-2020-7479 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 4.6 MEDIUM | 7.8 HIGH |
|
A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service.
|
|||||
| CVE-2020-7478 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated attacker to read arbitrary files from the IGSS server PC on an unrestricted or shared network when the IGSS Update Service is enabled.
|
|||||
| CVE-2020-7477 | 1 Schneider-electric | 56 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 53 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Quantum Ethernet Network module 140NOE771x1 (Versions 7.0 and prior), Quantum processors with integrated Ethernet – 140CPU65xxxxx (all Versions), and Premium processors with integrated Ethernet (all Versions), which could cause a Denial of Service when sending a specially crafted command over Modbus.
|
|||||
| CVE-2020-7476 | 1 Schneider-electric | 1 Ulti Zigbee Installation Toolkit | 2024-11-21 | 4.4 MEDIUM | 7.8 HIGH |
|
A CWE-426: Untrusted Search Path vulnerability exists in ZigBee Installation Kit (Versions prior to 1.0.1), which could cause execution of malicious code when a malicious file is put in the search path.
|
|||||
| CVE-2020-7475 | 1 Schneider-electric | 6 Ecostruxure Control Expert, Modicon M340, Modicon M340 Firmware and 3 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.
|
|||||
| CVE-2020-7474 | 1 Schneider-electric | 1 Pmepxm0100 Prosoft Configurator | 2024-11-21 | 4.4 MEDIUM | 7.8 HIGH |
|
A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProSoft Configurator (v1.002 and prior), for the PMEPXM0100 (H) module, which could cause the execution of untrusted code when using double click to open a project file which may trigger execution of a malicious DLL.
|
|||||
| CVE-2020-28221 | 1 Schneider-electric | 42 Ecostruxure Operator Terminal Expert, Gp-4104g, Gp-4104w and 39 more | 2024-11-21 | 9.3 HIGH | 9.8 CRITICAL |
|
A CWE-20: Improper Input Validation vulnerability exists in EcoStruxure™ Operator Terminal Expert and Pro-face BLUE (version details in the notification) that could cause arbitrary code execution when the Ethernet Download feature is enable on the HMI.
|
|||||
| CVE-2020-28220 | 1 Schneider-electric | 4 Modicon M258, Modicon M258 Firmware, Somachine and 1 more | 2024-11-21 | 5.2 MEDIUM | 6.8 MEDIUM |
|
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Modicon M258 Firmware (All versions prior to V5.0.4.11) and SoMachine/SoMachine Motion software (All versions), that could cause a buffer overflow when the length of a file transferred to the webserver is not verified.
|
|||||
| CVE-2020-28219 | 1 Schneider-electric | 2 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 | 2024-11-21 | 2.1 LOW | 7.8 HIGH |
|
A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from 83.7551.1 to 83.7578.1), that could cause exposure of credentials to server-side users when web users are logged in to Virtual ViewX.
|
|||||
| CVE-2020-28218 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2024-11-21 | 4.3 MEDIUM | 6.5 MEDIUM |
|
A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to trick a user into initiating an unintended action.
|
|||||
| CVE-2020-28217 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol.
|
|||||
| CVE-2020-28216 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol.
|
|||||
| CVE-2020-28215 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
A CWE-862: Missing Authorization vulnerability exists in Easergy T300 (firmware 2.7 and older), that could cause a wide range of problems, including information exposures, denial of service, and arbitrary code execution when access control checks are not applied consistently.
|
|||||
| CVE-2020-28214 | 1 Schneider-electric | 2 Modicon M221, Modicon M221 Firmware | 2024-11-21 | 2.1 LOW | 5.5 MEDIUM |
|
A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 (all references, all versions), that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection that an unpredictable salt would provide.
|
|||||
| CVE-2020-28213 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2024-11-21 | 6.5 MEDIUM | 8.8 HIGH |
|
A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus.
|
|||||
| CVE-2020-28212 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when a brute force attack is done over Modbus.
|
|||||
| CVE-2020-28211 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2024-11-21 | 4.6 MEDIUM | 7.8 HIGH |
|
A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger.
|
|||||
| CVE-2020-28210 | 1 Schneider-electric | 1 Ecostruxure Building Operation | 2024-11-21 | 4.3 MEDIUM | 6.1 MEDIUM |
|
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser.
|
|||||
| CVE-2020-28209 | 2 Microsoft, Schneider-electric | 2 Windows, Enterprise Server Installer | 2024-11-21 | 4.4 MEDIUM | 7.0 HIGH |
|
A CWE-428 Windows Unquoted Search Path vulnerability exists in EcoStruxure Building Operation Enterprise Server installer V1.9 - V3.1 and Enterprise Central installer V2.0 - V3.1 that could cause any local Windows user who has write permission on at least one of the subfolders of the Connect Agent service binary path, being able to gain the privilege of the user who started the service. By default, the Enterprise Server and Enterprise Central is always installed at a location requiring Administr ...
Show More |
|||||
| CVE-2020-25184 | 3 Rockwellautomation, Schneider-electric, Xylem | 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more | 2024-11-21 | 2.1 LOW | 7.8 HIGH |
|
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
|
|||||
| CVE-2020-25182 | 3 Rockwellautomation, Schneider-electric, Xylem | 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more | 2024-11-21 | 4.6 MEDIUM | 6.7 MEDIUM |
|
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.
|
|||||
| CVE-2020-25180 | 3 Rockwellautomation, Schneider-electric, Xylem | 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more | 2024-11-21 | 4.3 MEDIUM | 5.3 MEDIUM |
|
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device.
|
|||||
| CVE-2020-25178 | 3 Rockwellautomation, Schneider-electric, Xylem | 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more | 2024-11-21 | 9.3 HIGH | 7.5 HIGH |
|
ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files.
|
|||||
| CVE-2020-25176 | 3 Rockwellautomation, Schneider-electric, Xylem | 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more | 2024-11-21 | 9.3 HIGH | 9.1 CRITICAL |
|
Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an application’s directory, which could lead to remote code execution.
|
|||||
| CVE-2020-10626 | 2 Fazecast, Schneider-electric | 2 Jserialcomm, Ecostruxure It Gateway | 2024-11-21 | 6.9 MEDIUM | 7.8 HIGH |
|
In Fazecast jSerialComm, Version 2.2.2 and prior, an uncontrolled search path element vulnerability could allow a malicious DLL file with the same name of any resident DLLs inside the software installation to execute arbitrary code.
|
|||||
| CVE-2019-6859 | 1 Schneider-electric | 20 140 Cpu6x, 140 Cpu6x Firmware, 140 Noc 77101 and 17 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A CWE-798: Use of Hardcoded Credentials vulnerability exists in Modicon Controllers (All versions of the following CPUs and Communication Module product references listed in the Security Notifications), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.
|
|||||
| CVE-2019-6858 | 1 Schneider-electric | 1 Msx Configurator | 2024-11-21 | 4.4 MEDIUM | 7.8 HIGH |
|
A CWE-427:Uncontrolled Search Path Element vulnerability exists in MSX Configurator (Software Version prior to V1.0.8.1), which could cause privilege escalation when injecting a malicious DLL.
|
|||||
| CVE-2019-6857 | 1 Schneider-electric | 58 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 55 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP.
|
|||||
| CVE-2019-6856 | 1 Schneider-electric | 58 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 55 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.
|
|||||
| CVE-2019-6855 | 1 Schneider-electric | 44 Ecostruxure Control Expert, Modicon M340 Bmxp341000, Modicon M340 Bmxp341000 Firmware and 41 more | 2024-11-21 | 7.5 HIGH | 7.3 HIGH |
|
Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.
|
|||||
| CVE-2019-6854 | 1 Schneider-electric | 1 Clearscada | 2024-11-21 | 4.6 MEDIUM | 7.8 HIGH |
|
A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the file system of that operating system to exploit this vulnerability. Affected versions in current support includes ClearSCADA 2017 R3, ClearSCADA 2017 R2, and ClearSCADA 2017.
|
|||||
| CVE-2019-6853 | 1 Schneider-electric | 22 Andover Continuum 5720, Andover Continuum 5720 Firmware, Andover Continuum 5740 and 19 more | 2024-11-21 | 4.3 MEDIUM | 6.1 MEDIUM |
|
A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server.
|
|||||
| CVE-2019-6852 | 1 Schneider-electric | 20 140 Cpu6x, 140 Cpu6x Firmware, 140 Noc 77101 and 17 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A CWE-200: Information Exposure vulnerability exists in Modicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.
|
|||||
| CVE-2019-6851 | 1 Schneider-electric | 46 Modicon M340, Modicon M340 Firmware, Modicon M580 and 43 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol.
|
|||||
| CVE-2019-6850 | 1 Schneider-electric | 6 Modicon Bmenoc 0311, Modicon Bmenoc 0311 Firmware, Modicon Bmenoc 0321 and 3 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module.
|
|||||
| CVE-2019-6849 | 1 Schneider-electric | 6 Modicon Bmenoc 0311, Modicon Bmenoc 0311 Firmware, Modicon Bmenoc 0321 and 3 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module.
|
|||||
| CVE-2019-6848 | 1 Schneider-electric | 6 Modicon Bmenoc 0311, Modicon Bmenoc 0311 Firmware, Modicon Bmenoc 0321 and 3 more | 2024-11-21 | 5.0 MEDIUM | 8.6 HIGH |
|
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module.
|
|||||
| CVE-2019-6847 | 1 Schneider-electric | 8 Modicon 140cra, Modicon 140cra Firmware, Modicon Bmxcra and 5 more | 2024-11-21 | 4.0 MEDIUM | 4.9 MEDIUM |
|
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the FTP service when upgrading the firmware with a version incompatible with the application in the controller using FTP protocol.
|
|||||
| CVE-2019-6846 | 1 Schneider-electric | 8 Modicon 140cra, Modicon 140cra Firmware, Modicon Bmxcra and 5 more | 2024-11-21 | 4.3 MEDIUM | 6.5 MEDIUM |
|
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol.
|
|||||