Total
4 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2021-31894 | 1 Siemens | 8 Simatic Pcs 7, Simatic Pcs 7 Firmware, Simatic Pdm and 5 more | 2024-11-21 | 7.2 HIGH | 8.8 HIGH |
|
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipu ...
Show More |
|||||
| CVE-2021-31893 | 1 Siemens | 8 Simatic Pcs, Simatic Pcs Firmware, Simatic Pdm and 5 more | 2024-11-21 | 7.2 HIGH | 7.8 HIGH |
|
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code exec ...
Show More |
|||||
| CVE-2020-7586 | 1 Siemens | 4 Simatic Pcs 7, Simatic Process Device Manager, Simatic Step 7 and 1 more | 2024-11-21 | 4.6 MEDIUM | 7.8 HIGH |
|
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. S ...
Show More |
|||||
| CVE-2020-7585 | 1 Siemens | 4 Simatic Pcs 7, Simatic Process Device Manager, Simatic Step 7 and 1 more | 2024-11-21 | 4.6 MEDIUM | 7.8 HIGH |
|
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. S ...
Show More |
|||||