Total
12 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2017-12736 | 1 Siemens | 15 Ruggedcom, Ruggedcom Ros, Ruggedcom Rsl910 and 12 more | 2025-08-12 | 5.8 MEDIUM | 8.8 HIGH |
|
After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain conditions.
This could allow an attacker located in the adjacent network of the targeted device to perform unauthorized administrative actions.
|
|||||
| CVE-2020-28400 | 1 Siemens | 157 Dk Standard Ethernet Controller Evaluation Kit, Dk Standard Ethernet Controller Evaluation Kit Firmware, Ek-ertec 200 Evaulation Kit and 154 more | 2024-12-10 | 5.0 MEDIUM | 7.5 HIGH |
|
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
|
|||||
| CVE-2022-36325 | 1 Siemens | 180 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 177 more | 2024-11-21 | N/A | 6.8 MEDIUM |
|
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.
|
|||||
| CVE-2022-36324 | 1 Siemens | 168 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 165 more | 2024-11-21 | N/A | 7.5 HIGH |
|
Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.
|
|||||
| CVE-2022-36323 | 1 Siemens | 180 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 177 more | 2024-11-21 | N/A | 9.1 CRITICAL |
|
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.
|
|||||
| CVE-2021-3449 | 12 Checkpoint, Debian, Fedoraproject and 9 more | 167 Multi-domain Management, Multi-domain Management Firmware, Quantum Security Gateway and 164 more | 2024-11-21 | 4.3 MEDIUM | 5.9 MEDIUM |
|
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). O ...
Show More |
|||||
| CVE-2021-25667 | 1 Siemens | 30 Ruggedcom Rm1224, Ruggedcom Rm1224 Firmware, Scalance M-800 and 27 more | 2024-11-21 | 5.8 MEDIUM | 8.8 HIGH |
|
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR50 ...
Show More |
|||||
| CVE-2019-6569 | 1 Siemens | 10 Scalance X-200, Scalance X-200 Firmware, Scalance X-300 and 7 more | 2024-11-21 | 6.4 MEDIUM | 9.1 CRITICAL |
|
The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.
|
|||||
| CVE-2019-19301 | 1 Siemens | 26 Scalance X-200irt, Scalance X-200irt Firmware, Scalance X-200irt Pro and 23 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 ...
Show More |
|||||
| CVE-2019-13946 | 1 Siemens | 101 Dk Standard Ethernet Controller, Ek-ertec 200, Ek-ertec 200 Firmware and 98 more | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
|
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit
internal resource allocation when multiple legitimate diagnostic package
requests are sent to the DCE-RPC interface.
This could lead to a denial of service condition due to lack of memory
for devices that include a vulnerable version of the stack.
The security vulnerability could be exploited by an attacker with network
access to an affected device. Successful exploitation requires no system
privileges and no user interaction. ...
Show More |
|||||
| CVE-2019-13924 | 1 Siemens | 16 Scalance X-200irt, Scalance X-200irt Firmware, Scalance X-300 and 13 more | 2024-11-21 | 4.3 MEDIUM | 5.4 MEDIUM |
|
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3 ...
Show More |
|||||
| CVE-2019-10927 | 1 Siemens | 10 Scalance Xb-200, Scalance Xb-200 Firmware, Scalance Xc-200 and 7 more | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
|
A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with network access to the affected device. No user interaction is required to exploit this vulnerability. The ...
Show More |
|||||