Total
6 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2020-12005 | 1 Rockwellautomation | 2 Factorytalk Linx, Rslinx Classic | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
|
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to uplo ...
Show More |
|||||
| CVE-2020-12003 | 1 Rockwellautomation | 2 Factorytalk Linx, Rslinx Classic | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanit ...
Show More |
|||||
| CVE-2020-12001 | 1 Rockwellautomation | 2 Factorytalk Linx, Rslinx Classic | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input ...
Show More |
|||||
| CVE-2020-11999 | 1 Rockwellautomation | 2 Factorytalk Linx, Rslinx Classic | 2024-11-21 | 5.5 MEDIUM | 8.1 HIGH |
|
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanit ...
Show More |
|||||
| CVE-2020-10642 | 1 Rockwellautomation | 1 Rslinx Classic | 2024-11-21 | 7.2 HIGH | 7.8 HIGH |
|
In Rockwell Automation RSLinx Classic versions 4.11.00 and prior, an authenticated local attacker could modify a registry key, which could lead to the execution of malicious code using system privileges when opening RSLinx Classic.
|
|||||
| CVE-2018-10619 | 1 Rockwellautomation | 2 Factorytalk Linx Gateway, Rslinx Classic | 2024-11-21 | 4.6 MEDIUM | 7.8 HIGH |
|
An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.
|
|||||