Total
2 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2020-8349 | 1 Lenovo | 10 Cloud Networking Operating System, Rackswitch G8272, Rackswitch G8296 and 7 more | 2024-11-21 | 6.8 MEDIUM | 9.8 CRITICAL |
|
An internal security review has identified an unauthenticated remote code execution vulnerability in Cloud Networking Operating System (CNOS)’ optional REST API management interface. This interface is disabled by default and not vulnerable unless enabled. When enabled, it is only vulnerable where attached to a VRF and as allowed by defined ACLs. Lenovo strongly recommends upgrading to a non-vulnerable CNOS release. Where not possible, Lenovo recommends disabling the REST API management interface ...
Show More |
|||||
| CVE-2017-3765 | 2 Ibm, Lenovo | 30 1g L2-7 Slb Switch For Bladecenter, Bladecenter 1\, Bladecenter Layer 2\/3 Copper Ethernet Switch Module and 27 more | 2024-11-21 | 6.2 MEDIUM | 7.0 HIGH |
|
In Enterprise Networking Operating System (ENOS) in Lenovo and IBM RackSwitch and BladeCenter products, an authentication bypass known as "HP Backdoor" was discovered during a Lenovo security audit in the serial console, Telnet, SSH, and Web interfaces. This bypass mechanism can be accessed when performing local authentication under specific circumstances. If exploited, admin-level access to the switch is granted.
|
|||||