Vulnerabilities (CVE)

Filtered by vendor Tenda
Filtered by product Ac8
Angry Yack Logo
Total 45 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2026-3044 1 Tenda 2 Ac8, Ac8 Firmware 2026-02-24 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda AC8 16.03.34.06. This affects the function webCgiGetUploadFile of the file /cgi-bin/UploadCfg of the component Httpd Service. The manipulation of the argument boundary leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2026-2202 1 Tenda 2 Ac8, Ac8 Firmware 2026-02-10 9.0 HIGH 8.8 HIGH
A vulnerability was detected in Tenda AC8 16.03.33.05. Affected is the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet of the component httpd. The manipulation of the argument shareSpeed results in buffer overflow. The attack may be launched remotely. The exploit is now public and may be used.
CVE-2026-2203 1 Tenda 2 Ac8, Ac8 Firmware 2026-02-10 9.0 HIGH 8.8 HIGH
A flaw has been found in Tenda AC8 16.03.33.05. Affected by this vulnerability is an unknown functionality of the file /goform/fast_setting_wifi_set of the component Embedded Httpd Service. This manipulation of the argument timeZone causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used.
CVE-2025-61498 1 Tenda 2 Ac8, Ac8 Firmware 2025-12-08 N/A 7.5 HIGH
A buffer overflow in the UPnP service of Tenda AC8 Hardware v03.03.10.01 allows attackers to cause a Denial of Service (DoS) via supplying a crafted packet.
CVE-2025-12618 1 Tenda 2 Ac8, Ac8 Firmware 2025-11-05 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda AC8 16.03.34.06. This impacts an unknown function of the file /goform/DatabaseIniSet. The manipulation of the argument Time leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-52054 1 Tenda 2 Ac8, Ac8 Firmware 2025-09-09 N/A 5.3 MEDIUM
An issue was discovered in Tenda AC8 v4.0 AC1200 Dual-band Gigabit Wireless Router AC8v4.0 Firmware 16.03.33.05. The root password of the device is calculated with a static string and the last two octets of the MAC address of the device. This allows an unauthenticated attacker to authenticate with network services on the device.
CVE-2025-55852 1 Tenda 2 Ac8, Ac8 Firmware 2025-09-08 N/A 7.5 HIGH
Tenda AC8 v16.03.34.06 is vulnerable to Buffer Overflow in the formWifiBasicSet function via the parameter security or security_5g.
CVE-2025-51089 1 Tenda 2 Ac8, Ac8 Firmware 2025-07-28 N/A 6.5 MEDIUM
Tenda AC8V4 V16.03.34.06` was discovered to contain heap overflow at /goform/GetParentControlInfo.The manipulation of the argument `mac` leads to heap-based buffer overflow.
CVE-2025-51088 1 Tenda 2 Ac8, Ac8 Firmware 2025-07-28 N/A 5.3 MEDIUM
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/WifiGuestSet. The manipulation of the argument `shareSpeed` leads to stack-based buffer overflow.
CVE-2025-51087 1 Tenda 2 Ac8, Ac8 Firmware 2025-07-28 N/A 8.6 HIGH
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow.
CVE-2025-51085 1 Tenda 2 Ac8, Ac8 Firmware 2025-07-28 N/A 5.3 MEDIUM
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/SetSysTimeCfg. The manipulation of the argument `timeZone` and `timeType` leads to stack-based buffer overflow.
CVE-2025-51082 1 Tenda 2 Ac8, Ac8 Firmware 2025-07-28 N/A 5.3 MEDIUM
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/fast_setting_wifi_set. The manipulation of the argument `timeZone` leads to stack-based buffer overflow.
CVE-2025-5798 1 Tenda 2 Ac8, Ac8 Firmware 2025-06-09 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC8 16.03.34.09. It has been classified as critical. Affected is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeType leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-5799 1 Tenda 2 Ac8, Ac8 Firmware 2025-06-09 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-0528 1 Tenda 6 Ac10, Ac10 Firmware, Ac18 and 3 more 2025-05-28 8.3 HIGH 7.2 HIGH
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-4368 1 Tenda 2 Ac8, Ac8 Firmware 2025-05-13 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, was found in Tenda AC8 16.03.34.06. Affected is the function formGetRouterStatus of the file /goform/MtuSetMacWan. The manipulation of the argument shareSpeed leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-25510 1 Tenda 2 Ac8, Ac8 Firmware 2025-04-10 N/A 6.5 MEDIUM
Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the get_parentControl_list_Info function.
CVE-2025-29118 1 Tenda 2 Ac8, Ac8 Firmware 2025-04-01 N/A 6.5 MEDIUM
Tenda AC8 V16.03.34.06 was discovered to contain a stack overflow via the src parameter in the function sub_47D878.
CVE-2025-29100 1 Tenda 2 Ac8, Ac8 Firmware 2025-04-01 N/A 9.8 CRITICAL
Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the fromSetRouteStatic function via the parameter list.
CVE-2025-29101 1 Tenda 2 Ac8, Ac8 Firmware 2025-03-25 N/A 7.5 HIGH
Tenda AC8V4.0 V16.03.34.06 was discovered to contain a stack overflow via the deviceid parameter in the get_parentControl_list_Info function.
CVE-2025-25667 1 Tenda 2 Ac8, Ac8 Firmware 2025-03-17 N/A 9.8 CRITICAL
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info.
CVE-2025-25668 1 Tenda 2 Ac8, Ac8 Firmware 2025-03-17 N/A 9.8 CRITICAL
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_47D878 function.
CVE-2025-25664 1 Tenda 2 Ac8, Ac8 Firmware 2025-03-17 N/A 9.8 CRITICAL
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_49E098 function.
CVE-2025-25663 1 Tenda 2 Ac8, Ac8 Firmware 2025-03-17 N/A 9.8 CRITICAL
A vulnerability was found in Tenda AC8V4 V16.03.34.06. Affected is the function SUB_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow.
CVE-2024-57704 1 Tenda 2 Ac8, Ac8 Firmware 2025-03-17 N/A 8.8 HIGH
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow.
CVE-2024-46652 1 Tenda 2 Ac8, Ac8 Firmware 2025-03-17 N/A 9.8 CRITICAL
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability in the fromAdvSetMacMtuWan function.
CVE-2024-57703 1 Tenda 2 Ac8, Ac8 Firmware 2025-03-17 N/A 9.8 CRITICAL
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow.
CVE-2025-1853 1 Tenda 2 Ac8, Ac8 Firmware 2025-03-05 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC8 16.03.34.06 and classified as critical. This issue affects the function sub_49E098 of the file /goform/SetIpMacBind of the component Parameter Handler. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-4064 1 Tenda 2 Ac8, Ac8 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond ...

Show More

CVE-2024-4065 1 Tenda 2 Ac8, Ac8 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any ...

Show More

CVE-2024-4066 1 Tenda 2 Ac8, Ac8 Firmware 2025-01-21 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclo ...

Show More

CVE-2023-33675 1 Tenda 2 Ac8, Ac8 Firmware 2025-01-08 N/A 9.8 CRITICAL
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function.
CVE-2023-33673 1 Tenda 2 Ac8, Ac8 Firmware 2025-01-08 N/A 9.8 CRITICAL
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
CVE-2023-33672 1 Tenda 2 Ac8, Ac8 Firmware 2025-01-08 N/A 7.5 HIGH
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function.
CVE-2023-33671 1 Tenda 2 Ac8, Ac8 Firmware 2025-01-08 N/A 9.8 CRITICAL
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function.
CVE-2023-33670 1 Tenda 2 Ac8, Ac8 Firmware 2025-01-08 N/A 9.8 CRITICAL
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function.
CVE-2023-33669 1 Tenda 2 Ac8, Ac8 Firmware 2025-01-08 N/A 9.8 CRITICAL
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub_44db3c function.
CVE-2024-11745 1 Tenda 2 Ac8, Ac8 Firmware 2024-12-03 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2023-4744 1 Tenda 2 Ac8, Ac8 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.
CVE-2023-38937 1 Tenda 14 Ac10, Ac10 Firmware, Ac1206 and 11 more 2024-11-21 N/A 9.8 CRITICAL
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.