Total
102 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2025-11326 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-02-24 | 9.0 HIGH | 8.8 HIGH |
|
A weakness has been identified in Tenda AC18 15.03.05.19(6318). This affects an unknown part of the file /goform/WifiMacFilterSet. Executing a manipulation of the argument wifi_chkHz can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks.
|
|||||
| CVE-2025-11325 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-02-24 | 9.0 HIGH | 8.8 HIGH |
|
A security flaw has been discovered in Tenda AC18 15.03.05.19(6318). Affected by this issue is some unknown functionality of the file /goform/fast_setting_pppoe_set. Performing a manipulation of the argument Username results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.
|
|||||
| CVE-2025-14992 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-12-31 | 9.0 HIGH | 8.8 HIGH |
|
A security vulnerability has been detected in Tenda AC18 15.03.05.05. The impacted element is the function strcpy of the file /goform/GetParentControlInfo of the component HTTP Request Handler. The manipulation of the argument mac leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used.
|
|||||
| CVE-2025-14993 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-12-31 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was detected in Tenda AC18 15.03.05.05. This affects the function sprintf of the file /goform/SetDlnaCfg of the component HTTP Request Handler. The manipulation of the argument scanList results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used.
|
|||||
| CVE-2025-63834 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-12-01 | N/A | 5.4 MEDIUM |
|
A stored cross-site scripting (XSS) vulnerability was discovered in Tenda AC18 v15.03.05.05_multi. The vulnerability exists in the ssid parameter of the wireless settings. Remote attackers can inject malicious payloads that execute when any user visits the router's homepage.
|
|||||
| CVE-2025-63835 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-11-18 | N/A | 8.8 HIGH |
|
A stack-based buffer overflow vulnerability was discovered in Tenda AC18 v15.03.05.05_multi. The vulnerability exists in the guestSsid parameter of the /goform/WifiGuestSet interface. Remote attackers can exploit this vulnerability by sending oversized data to the guestSsid parameter, leading to denial of service (device crash) or potential remote code execution.
|
|||||
| CVE-2025-60660 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-07 | N/A | 7.5 HIGH |
|
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the mac parameter in the fromAdvSetMacMtuWan function.
|
|||||
| CVE-2025-60662 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-07 | N/A | 7.5 HIGH |
|
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the wanSpeed parameter in the fromAdvSetMacMtuWan function.
|
|||||
| CVE-2025-60663 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-07 | N/A | 7.5 HIGH |
|
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the wanMTU parameter in the fromAdvSetMacMtuWan function.
|
|||||
| CVE-2025-60661 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-07 | N/A | 5.3 MEDIUM |
|
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the cloneType parameter in the fromAdvSetMacMtuWan function.
|
|||||
| CVE-2025-11324 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-07 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was identified in Tenda AC18 15.03.05.19(6318). Affected by this vulnerability is an unknown functionality of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.
|
|||||
| CVE-2025-11327 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-07 | 9.0 HIGH | 8.8 HIGH |
|
A security vulnerability has been detected in Tenda AC18 15.03.05.19(6318). This vulnerability affects unknown code of the file /goform/SetUpnpCfg. The manipulation of the argument upnpEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used.
|
|||||
| CVE-2025-11328 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-07 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was detected in Tenda AC18 15.03.05.19(6318). This issue affects some unknown processing of the file /goform/SetDDNSCfg. The manipulation of the argument ddnsEn results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is now public and may be used.
|
|||||
| CVE-2025-9023 | 1 Tenda | 4 Ac18, Ac18 Firmware, Ac7 and 1 more | 2025-10-03 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
|
|||||
| CVE-2025-11123 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-03 | 9.0 HIGH | 8.8 HIGH |
|
A flaw has been found in Tenda AC18 15.03.05.19. This impacts an unknown function of the file /goform/saveAutoQos. This manipulation of the argument enable causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been published and may be used.
|
|||||
| CVE-2025-11122 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-03 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was detected in Tenda AC18 15.03.05.19. This affects an unknown function of the file /goform/WizardHandle. The manipulation of the argument WANT/mtuvalue results in stack-based buffer overflow. The attack can be launched remotely. The exploit is now public and may be used.
|
|||||
| CVE-2025-11121 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-03 | 6.5 MEDIUM | 6.3 MEDIUM |
|
A security vulnerability has been detected in Tenda AC18 15.03.05.19. The impacted element is an unknown function of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.
|
|||||
| CVE-2025-11120 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-03 | 9.0 HIGH | 8.8 HIGH |
|
A weakness has been identified in Tenda AC8 16.03.34.06. The affected element is the function formSetServerConfig of the file /goform/SetServerConfig. Executing manipulation can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been made available to the public and could be exploited.
|
|||||
| CVE-2025-8182 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-08-01 | 5.1 MEDIUM | 5.6 MEDIUM |
|
A vulnerability has been found in Tenda AC18 15.03.05.19 and classified as problematic. This vulnerability affects unknown code of the file /etc_ro/smb.conf of the component Samba. The manipulation leads to weak password requirements. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used.
|
|||||
| CVE-2025-5609 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-06-17 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
|
|||||
| CVE-2025-5608 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-06-17 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formsetreboottimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
|
|||||
| CVE-2025-5607 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-06-17 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
|
|||||
| CVE-2025-5606 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-06-10 | 6.5 MEDIUM | 6.3 MEDIUM |
|
A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetIptv of the file /goform/SetIPTVCfg. The manipulation of the argument list leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
|
|||||
| CVE-2023-38823 | 1 Tenda | 8 Ac18, Ac18 Firmware, Ac19 and 5 more | 2025-06-10 | N/A | 9.8 CRITICAL |
|
Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd.
|
|||||
| CVE-2025-0528 | 1 Tenda | 6 Ac10, Ac10 Firmware, Ac18 and 3 more | 2025-05-28 | 8.3 HIGH | 7.2 HIGH |
|
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
|
|||||
| CVE-2022-40861 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-05-22 | N/A | 7.2 HIGH |
|
Tenda AC18 router V15.03.05.19 contains a stack overflow vulnerability in the formSetQosBand->FUN_0007db78 function with the request /goform/SetNetControlList/
|
|||||
| CVE-2022-40854 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-05-22 | N/A | 9.8 CRITICAL |
|
Tenda AC18 router contained a stack overflow vulnerability in /goform/fast_setting_wifi_set
|
|||||
| CVE-2022-43260 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-05-12 | N/A | 9.8 CRITICAL |
|
Tenda AC18 V15.03.05.19(6318) was discovered to contain a stack overflow via the time parameter in the fromSetSysTime function.
|
|||||
| CVE-2022-44172 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-29 | N/A | 9.8 CRITICAL |
|
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function R7WebsSecurityHandler.
|
|||||
| CVE-2022-44171 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-29 | N/A | 9.8 CRITICAL |
|
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function form_fast_setting_wifi_set.
|
|||||
| CVE-2022-44183 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-29 | N/A | 9.8 CRITICAL |
|
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetWifiGuestBasic.
|
|||||
| CVE-2022-44180 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-29 | N/A | 9.8 CRITICAL |
|
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function addWifiMacFilter.
|
|||||
| CVE-2022-44178 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-29 | N/A | 9.8 CRITICAL |
|
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow. via function formWifiWpsOOB.
|
|||||
| CVE-2022-44177 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-29 | N/A | 9.8 CRITICAL |
|
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formWifiWpsStart.
|
|||||
| CVE-2022-44176 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-29 | N/A | 9.8 CRITICAL |
|
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function fromSetRouteStatic.
|
|||||
| CVE-2022-44175 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-29 | N/A | 9.8 CRITICAL |
|
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetMacFilterCfg.
|
|||||
| CVE-2022-44174 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-29 | N/A | 9.8 CRITICAL |
|
Tenda AC18 V15.03.05.05 is vulnerable to Buffer Overflow via function formSetDeviceName.
|
|||||
| CVE-2017-16923 | 1 Tenda | 6 Ac15, Ac15 Firmware, Ac18 and 3 more | 2025-04-20 | 8.3 HIGH | 8.8 HIGH |
|
Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the "sub_ ...
Show More |
|||||
| CVE-2017-16936 | 1 Tenda | 6 Ac15, Ac15 Firmware, Ac18 and 3 more | 2025-04-20 | 3.3 LOW | 6.5 MEDIUM |
|
Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1&path= URI that uses directory traversal sequences after a /usb/ substring.
|
|||||
| CVE-2024-30891 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-04-10 | N/A | 8.8 HIGH |
|
A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution.
|
|||||