Filtered by vendor Schneider-electric
Subscribe
Total
759 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-37198 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 6.8 MEDIUM |
|
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that
could cause remote code execution when an admin user on DCE uploads or tampers with install
packages.
|
|||||
| CVE-2023-37197 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 8.8 HIGH |
|
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command
('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to
access unauthorized content, change, or delete content, or perform unauthorized actions when
tampering with the mass configuration settings of endpoints on DCE.
|
|||||
| CVE-2023-37196 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 8.8 HIGH |
|
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command
('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to
access unauthorized content, change, or delete content, or perform unauthorized actions when
tampering with the alert settings of endpoints on DCE.
|
|||||
| CVE-2023-2570 | 1 Schneider-electric | 1 Ecostruxure Foxboro Dcs Control Core Services | 2024-11-21 | N/A | 7.0 HIGH |
|
A CWE-129: Improper Validation of Array Index vulnerability exists that could cause local
denial-of-service, and potentially kernel execution when a malicious actor with local user access
crafts a script/program using an unpredictable index to an IOCTL call in the Foxboro.sys driver.
|
|||||
| CVE-2023-2569 | 1 Schneider-electric | 1 Ecostruxure Foxboro Dcs Control Core Services | 2024-11-21 | N/A | 7.8 HIGH |
|
A CWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service,
elevation of privilege, and potentially kernel execution when a malicious actor with local user
access crafts a script/program using an IOCTL call in the Foxboro.sys driver.
|
|||||
| CVE-2023-2161 | 1 Schneider-electric | 1 Opc Factory Server | 2024-11-21 | N/A | 5.0 MEDIUM |
|
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that
could cause unauthorized read access to the file system when a malicious configuration file is
loaded on to the software by a local user.
|
|||||
| CVE-2023-29414 | 1 Schneider-electric | 1 Accutech Manager | 2024-11-21 | N/A | 7.8 HIGH |
|
A CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability
exists that could cause user privilege escalation if a local user sends specific string input to a
local function call.
|
|||||
| CVE-2023-29413 | 2 Microsoft, Schneider-electric | 7 Windows 10, Windows 11, Windows Server 2016 and 4 more | 2024-11-21 | N/A | 7.5 HIGH |
|
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause
Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor
service.
|
|||||
| CVE-2023-29412 | 2 Microsoft, Schneider-electric | 7 Windows 10, Windows 11, Windows Server 2016 and 4 more | 2024-11-21 | N/A | 9.8 CRITICAL |
|
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command
Injection') vulnerability exists that could cause remote code execution when manipulating
internal methods through Java RMI interface.
|
|||||
| CVE-2023-29411 | 2 Microsoft, Schneider-electric | 7 Windows 10, Windows 11, Windows Server 2016 and 4 more | 2024-11-21 | N/A | 9.8 CRITICAL |
|
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow
changes to administrative credentials, leading to potential remote code execution without
requiring prior authentication on the Java RMI interface.
|
|||||
| CVE-2023-29410 | 1 Schneider-electric | 6 Conext Gateway, Conext Gateway Firmware, Insightfacility and 3 more | 2024-11-21 | N/A | 7.2 HIGH |
|
A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated
attacker to gain the same privilege as the application on the server when a malicious payload is
provided over HTTP for the server to execute.
|
|||||
| CVE-2023-28004 | 1 Schneider-electric | 2 Powerlogic Hdpm6000, Powerlogic Hdpm6000 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
|
A CWE-129: Improper validation of an array index vulnerability exists where a specially crafted
Ethernet request could result in denial of service or remote code execution.
|
|||||
| CVE-2023-28003 | 1 Schneider-electric | 1 Ecostruxure Power Monitoring Expert | 2024-11-21 | N/A | 6.7 MEDIUM |
|
A CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to
maintain unauthorized access over a hijacked session in PME after the legitimate user has
signed out of their account.
|
|||||
| CVE-2023-27984 | 1 Schneider-electric | 3 Custom Reports, Igss Dashboard, Igss Data Server | 2024-11-21 | N/A | 7.8 HIGH |
|
A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, potentially leading to remote code execution when a user opens a malicious report file planted by an attacker. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
|
|||||
| CVE-2023-27983 | 1 Schneider-electric | 3 Custom Reports, Igss Dashboard, Igss Data Server | 2024-11-21 | N/A | 6.5 MEDIUM |
|
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow deletion of reports from the IGSS project report directory, this would lead to loss of data when an attacker abuses this functionality. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
|
|||||
| CVE-2023-27982 | 1 Schneider-electric | 3 Custom Reports, Igss Dashboard, Igss Data Server | 2024-11-21 | N/A | 8.8 HIGH |
|
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS project report directory, when an attacker sends specific crafted messages to the Data Server TCP port, this could lead to remote code execution when a victim eventually opens a malicious dashboard file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), ...
Show More |
|||||
| CVE-2023-27981 | 1 Schneider-electric | 3 Custom Reports, Igss Dashboard, Igss Data Server | 2024-11-21 | N/A | 7.8 HIGH |
|
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Custom Reports that could cause a remote code execution when a victim tries to open a malicious report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
|
|||||
| CVE-2023-27980 | 1 Schneider-electric | 3 Custom Reports, Igss Dashboard, Igss Data Server | 2024-11-21 | N/A | 8.8 HIGH |
|
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)
|
|||||
| CVE-2023-27979 | 1 Schneider-electric | 3 Custom Reports, Igss Dashboard, Igss Data Server | 2024-11-21 | N/A | 6.5 MEDIUM |
|
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could allow the renaming of files in the IGSS project report directory, this could lead to denial of service when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
|
|||||
| CVE-2023-27978 | 1 Schneider-electric | 3 Custom Reports, Igss Dashboard, Igss Data Server | 2024-11-21 | N/A | 7.8 HIGH |
|
A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
|
|||||
| CVE-2023-27977 | 1 Schneider-electric | 3 Custom Reports, Igss Dashboard, Igss Data Server | 2024-11-21 | N/A | 6.5 MEDIUM |
|
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
|
|||||
| CVE-2023-27976 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2024-11-21 | N/A | 8.8 HIGH |
|
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause
remote code execution when a valid user visits a malicious link provided through the web
endpoints. Affected Products: EcoStruxure Control Expert (V15.1 and above)
|
|||||
| CVE-2023-25620 | 1 Schneider-electric | 16 140cpu65, 140cpu65 Firmware, Bmeh58s and 13 more | 2024-11-21 | N/A | 6.5 MEDIUM |
|
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that
could cause denial of service of the controller when a malicious project file is loaded onto the
controller by an authenticated user.
|
|||||
| CVE-2023-25556 | 1 Schneider-electric | 14 Merten Instabus Tastermodul 1fach System M, Merten Instabus Tastermodul 1fach System M Firmware, Merten Instabus Tastermodul 2fach System M and 11 more | 2024-11-21 | N/A | 8.3 HIGH |
|
A CWE-287: Improper Authentication vulnerability exists that could allow a device to be
compromised when a key of less than seven digits is entered and the attacker has access to the
KNX installation.
|
|||||
| CVE-2023-25555 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 5.6 MEDIUM |
|
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS
Command Injection') vulnerability exists that could allow a user that knows the credentials to
execute unprivileged shell commands on the appliance over SSH.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
|
|||||
| CVE-2023-25554 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 7.8 HIGH |
|
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS
Command Injection') vulnerability exists that allows a local privilege escalation on the appliance
when a maliciously crafted Operating System command is entered on the device.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
|
|||||
| CVE-2023-25553 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 6.1 MEDIUM |
|
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site
Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the
webserver.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
|
|||||
| CVE-2023-25552 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 8.1 HIGH |
|
A CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized
content, changes or deleting of content, or performing unauthorized functions when tampering
the Device File Transfer settings on DCE endpoints.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
|
|||||
| CVE-2023-25551 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 6.1 MEDIUM |
|
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site
Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters
over HTTP.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
|
|||||
| CVE-2023-25550 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 7.2 HIGH |
|
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that
allows remote code execution via the “hostname” parameter when maliciously crafted hostname
syntax is entered.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
|
|||||
| CVE-2023-25549 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 7.2 HIGH |
|
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that
allows for remote code execution when using a parameter of the DCE network settings
endpoint.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
|
|||||
| CVE-2023-25548 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 8.8 HIGH |
|
A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device
credentials on specific DCE endpoints not being properly secured when a hacker is using a low
privileged user.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
|
|||||
| CVE-2023-25547 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | N/A | 8.8 HIGH |
|
A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution
on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
|
|||||
| CVE-2023-22611 | 1 Schneider-electric | 3 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020, Ecostruxure Geo Scada Expert 2021 | 2024-11-21 | N/A | 7.5 HIGH |
|
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)
|
|||||
| CVE-2023-22610 | 1 Schneider-electric | 3 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020, Ecostruxure Geo Scada Expert 2021 | 2024-11-21 | N/A | 9.1 CRITICAL |
|
A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of
Service against the Geo SCADA server when specific messages are sent to the server over the
database server TCP port.
|
|||||
| CVE-2023-1548 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2024-11-21 | N/A | 5.5 MEDIUM |
|
A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to
perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above)
|
|||||
| CVE-2023-1049 | 1 Schneider-electric | 2 Ecostruxure Operator Terminal Expert, Pro-face Blue | 2024-11-21 | N/A | 7.8 HIGH |
|
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that
could cause execution of malicious code when an unsuspicious user loads a project file from the
local filesystem into the HMI.
|
|||||
| CVE-2023-0595 | 1 Schneider-electric | 4 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 and 1 more | 2024-11-21 | N/A | 5.3 MEDIUM |
|
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions)
|
|||||
| CVE-2022-4062 | 1 Schneider-electric | 1 Ecostruxure Power Commission | 2024-11-21 | N/A | 7.8 HIGH |
|
A CWE-285: Improper Authorization vulnerability exists that could cause unauthorized access to certain software functions when an attacker gets access to localhost interface of the EcoStruxure Power Commission application. Affected Products: EcoStruxure Power Commission (Versions prior to V2.25)
|
|||||
| CVE-2022-46680 | 1 Schneider-electric | 10 Powerlogic Ion7400, Powerlogic Ion7400 Firmware, Powerlogic Ion8650 and 7 more | 2024-11-21 | N/A | 8.8 HIGH |
|
A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could
cause disclosure of sensitive information, denial of service, or modification of data if an attacker
is able to intercept network traffic.
|
|||||