CVE-2023-37198 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 6.8 MEDIUM
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE uploads or tampers with install packages.
CVE-2023-37197 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 8.8 HIGH
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the mass configuration settings of endpoints on DCE.
CVE-2023-37196 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 8.8 HIGH
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the alert settings of endpoints on DCE.
CVE-2023-2570 1 Schneider-electric 1 Ecostruxure Foxboro Dcs Control Core Services 2024-11-21 N/A 7.0 HIGH
A CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service, and potentially kernel execution when a malicious actor with local user access crafts a script/program using an unpredictable index to an IOCTL call in the Foxboro.sys driver.
CVE-2023-2569 1 Schneider-electric 1 Ecostruxure Foxboro Dcs Control Core Services 2024-11-21 N/A 7.8 HIGH
A CWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service, elevation of privilege, and potentially kernel execution when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver.
CVE-2023-2161 1 Schneider-electric 1 Opc Factory Server 2024-11-21 N/A 5.0 MEDIUM
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized read access to the file system when a malicious configuration file is loaded on to the software by a local user. 
CVE-2023-29414 1 Schneider-electric 1 Accutech Manager 2024-11-21 N/A 7.8 HIGH
A CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability exists that could cause user privilege escalation if a local user sends specific string input to a local function call.
CVE-2023-29413 2 Microsoft, Schneider-electric 7 Windows 10, Windows 11, Windows Server 2016 and 4 more 2024-11-21 N/A 7.5 HIGH
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service.
CVE-2023-29412 2 Microsoft, Schneider-electric 7 Windows 10, Windows 11, Windows Server 2016 and 4 more 2024-11-21 N/A 9.8 CRITICAL
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface.
CVE-2023-29411 2 Microsoft, Schneider-electric 7 Windows 10, Windows 11, Windows Server 2016 and 4 more 2024-11-21 N/A 9.8 CRITICAL
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.
CVE-2023-29410 1 Schneider-electric 6 Conext Gateway, Conext Gateway Firmware, Insightfacility and 3 more 2024-11-21 N/A 7.2 HIGH
A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server when a malicious payload is provided over HTTP for the server to execute.
CVE-2023-28004 1 Schneider-electric 2 Powerlogic Hdpm6000, Powerlogic Hdpm6000 Firmware 2024-11-21 N/A 9.8 CRITICAL
A CWE-129: Improper validation of an array index vulnerability exists where a specially crafted Ethernet request could result in denial of service or remote code execution.
CVE-2023-28003 1 Schneider-electric 1 Ecostruxure Power Monitoring Expert 2024-11-21 N/A 6.7 MEDIUM
A CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain unauthorized access over a hijacked session in PME after the legitimate user has signed out of their account.
CVE-2023-27984 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 7.8 HIGH
A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, potentially leading to remote code execution when a user opens a malicious report file planted by an attacker. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27983 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 6.5 MEDIUM
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow deletion of reports from the IGSS project report directory, this would lead to loss of data when an attacker abuses this functionality. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27982 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 8.8 HIGH
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS project report directory, when an attacker sends specific crafted messages to the Data Server TCP port, this could lead to remote code execution when a victim eventually opens a malicious dashboard file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), ...

Show More

CVE-2023-27981 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 7.8 HIGH
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Custom Reports that could cause a remote code execution when a victim tries to open a malicious report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27980 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 8.8 HIGH
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)
CVE-2023-27979 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 6.5 MEDIUM
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could allow the renaming of files in the IGSS project report directory, this could lead to denial of service when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27978 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 7.8 HIGH
A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27977 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 6.5 MEDIUM
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27976 1 Schneider-electric 1 Ecostruxure Control Expert 2024-11-21 N/A 8.8 HIGH
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Control Expert (V15.1 and above)
CVE-2023-25620 1 Schneider-electric 16 140cpu65, 140cpu65 Firmware, Bmeh58s and 13 more 2024-11-21 N/A 6.5 MEDIUM
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when a malicious project file is loaded onto the controller by an authenticated user.
CVE-2023-25556 1 Schneider-electric 14 Merten Instabus Tastermodul 1fach System M, Merten Instabus Tastermodul 1fach System M Firmware, Merten Instabus Tastermodul 2fach System M and 11 more 2024-11-21 N/A 8.3 HIGH
A CWE-287: Improper Authentication vulnerability exists that could allow a device to be compromised when a key of less than seven digits is entered and the attacker has access to the KNX installation.
CVE-2023-25555 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 5.6 MEDIUM
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow a user that knows the credentials to execute unprivileged shell commands on the appliance over SSH. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25554 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 7.8 HIGH
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that allows a local privilege escalation on the appliance when a maliciously crafted Operating System command is entered on the device. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25553 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 6.1 MEDIUM
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the webserver. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25552 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 8.1 HIGH
A CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized content, changes or deleting of content, or performing unauthorized functions when tampering the Device File Transfer settings on DCE endpoints. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25551 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 6.1 MEDIUM
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters over HTTP. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25550 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 7.2 HIGH
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows remote code execution via the “hostname” parameter when maliciously crafted hostname syntax is entered. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25549 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 7.2 HIGH
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25548 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 8.8 HIGH
A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when a hacker is using a low privileged user. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25547 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 8.8 HIGH
A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-22611 1 Schneider-electric 3 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020, Ecostruxure Geo Scada Expert 2021 2024-11-21 N/A 7.5 HIGH
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)
CVE-2023-22610 1 Schneider-electric 3 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020, Ecostruxure Geo Scada Expert 2021 2024-11-21 N/A 9.1 CRITICAL
A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port.
CVE-2023-1548 1 Schneider-electric 1 Ecostruxure Control Expert 2024-11-21 N/A 5.5 MEDIUM
A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above)
CVE-2023-1049 1 Schneider-electric 2 Ecostruxure Operator Terminal Expert, Pro-face Blue 2024-11-21 N/A 7.8 HIGH
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause execution of malicious code when an unsuspicious user loads a project file from the local filesystem into the HMI.
CVE-2023-0595 1 Schneider-electric 4 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 and 1 more 2024-11-21 N/A 5.3 MEDIUM
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions)
CVE-2022-4062 1 Schneider-electric 1 Ecostruxure Power Commission 2024-11-21 N/A 7.8 HIGH
A CWE-285: Improper Authorization vulnerability exists that could cause unauthorized access to certain software functions when an attacker gets access to localhost interface of the EcoStruxure Power Commission application. Affected Products: EcoStruxure Power Commission (Versions prior to V2.25)
CVE-2022-46680 1 Schneider-electric 10 Powerlogic Ion7400, Powerlogic Ion7400 Firmware, Powerlogic Ion8650 and 7 more 2024-11-21 N/A 8.8 HIGH
A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic.