Filtered by vendor Siemens
Subscribe
Total
2143 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2019-19294 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-11-21 | 3.5 LOW | 6.3 MEDIUM |
|
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The web interface of the Control Center Server (CCS) contains
multiple stored Cross-site Scripting (XSS) vulnerabilities in several input
fields.
This could allow an authenticated remote attacker to inject malicious
JavaScript code into the CCS web application that is later executed
in the browser context of any other user who views the relevant CCS
web content.
|
|||||
| CVE-2019-19293 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-11-21 | 4.3 MEDIUM | 6.1 MEDIUM |
|
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The web interface of the Control Center Server (CCS) contains a
reflected Cross-site Scripting (XSS) vulnerability
that could allow an unauthenticated remote attacker to steal sensitive data
or execute administrative actions on behalf of a legitimate administrator
of the CCS web interface.
|
|||||
| CVE-2019-19292 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-11-21 | 6.5 MEDIUM | 8.8 HIGH |
|
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an SQL injection
vulnerability in its XML-based communication protocol as provided by default
on ports 5444/tcp and 5440/tcp.
An authenticated remote attacker could exploit this vulnerability to
read or modify the CCS database and potentially execute administrative
database operations or operating system commands.
|
|||||
| CVE-2019-19291 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-11-21 | 3.5 LOW | 5.3 MEDIUM |
|
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0), SiNVR/SiVMS Video Server (All versions < V5.0.0). The FTP services of the SiVMS/SiNVR Video Server and the Control Center Server (CCS) maintain
log files that store login credentials in cleartext.
In configurations where the FTP service is enabled, authenticated remote
attackers could extract login credentials of other users of the service.
|
|||||
| CVE-2019-19290 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
|
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The DOWNLOADS section in the web interface of the Control Center
Server (CCS) contains a path traversal vulnerability
that could allow an authenticated remote attacker to access and download
arbitrary files from the server where CCS is installed.
|
|||||
| CVE-2019-19289 | 1 Siemens | 1 Xhq | 2024-11-21 | 6.8 MEDIUM | 8.8 HIGH |
|
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link.
|
|||||
| CVE-2019-19288 | 1 Siemens | 1 Xhq | 2024-11-21 | 4.3 MEDIUM | 6.1 MEDIUM |
|
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link.
|
|||||
| CVE-2019-19287 | 1 Siemens | 1 Xhq | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
|
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow attackers to traverse through the file system of the server based by sending specially crafted packets over the network without authentication.
|
|||||
| CVE-2019-19286 | 1 Siemens | 1 Xhq | 2024-11-21 | 6.5 MEDIUM | 7.2 HIGH |
|
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow SQL injection attacks if an attacker is able to modify content of particular web pages.
|
|||||
| CVE-2019-19285 | 1 Siemens | 1 Xhq | 2024-11-21 | 3.5 LOW | 5.4 MEDIUM |
|
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow injections that could lead to XSS attacks if unsuspecting users are tricked into accessing a malicious link.
|
|||||
| CVE-2019-19284 | 1 Siemens | 1 Xhq | 2024-11-21 | 3.5 LOW | 5.4 MEDIUM |
|
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify content of particular web pages, causing the application to behave in unexpected ways for legitimate users.
|
|||||
| CVE-2019-19283 | 1 Siemens | 1 Xhq | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
|
A vulnerability has been identified in XHQ (All Versions < 6.1). The application's web server could expose non-sensitive information about the server's architecture. This could allow an attacker to adapt further attacks to the version in place.
|
|||||
| CVE-2019-19282 | 1 Siemens | 6 Openpcs 7, Simatic Batch, Simatic Net Pc and 3 more | 2024-11-21 | 7.1 HIGH | 7.5 HIGH |
|
A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 ( ...
Show More |
|||||
| CVE-2019-19281 | 1 Siemens | 28 Simatic Et 200sp Open Controller Cpu 1515sp Pc2, Simatic Et 200sp Open Controller Cpu 1515sp Pc2 Firmware, Simatic S7-1500 Cpu 1507s and 25 more | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
|
A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V2.5 and < V20.8), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 and < V2.8), SIMATIC S7-1500 Software Controller (All versions >= V2.5 and < V20.8). Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a Denial-of-Service condition. The vulnerability can be triggered if specially c ...
Show More |
|||||
| CVE-2019-19279 | 1 Siemens | 2 Siprotec 4, Siprotec Compact | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
|
A vulnerability has been identified in SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules (All versions). Specially crafted packets sent to port 50000/UDP of the EN100 Ethernet communication modules could cause a Denial-of-Service of the affected device. A manual reboot is required to recover the service of the device. At the time of advisory publication no public exploitation of this security vulnerability was known to Siemens.
|
|||||
| CVE-2019-19278 | 1 Siemens | 2 Sinamics Perfect Harmony Gh180, Sinamics Perfect Harmony Gh180 Firmware | 2024-11-21 | 7.2 HIGH | 6.8 MEDIUM |
|
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 Drives MLFB 6SR32..-.....-.... MLFB 6SR4...-.....-.... MLFB 6SR5...-.....-.... With option A30 (HMIs 12 inches or larger) (All versions), SINAMICS PERFECT HARMONY GH180 Drives MLFB 6SR325.-.....-.... (High Availability) (All versions). The affected device contains a vulnerability that could allow an unauthenticated attacker to restore the affected device to a point where predefined application and operating system protection m ...
Show More |
|||||
| CVE-2019-19277 | 1 Siemens | 1 Siport Mp | 2024-11-21 | 5.5 MEDIUM | 6.5 MEDIUM |
|
A vulnerability has been identified in SIPORT MP (All versions < 3.1.4). Vulnerable versions of the device allow the creation of special accounts ("service users") with administrative privileges that could enable a remote authenticated attacker to perform actions that are not visible to other users of the system, such as granting persons access to a secured area.
|
|||||
| CVE-2019-19276 | 1 Siemens | 4 Simatic Hmi Comfort Panels, Simatic Hmi Comfort Panels Firmware, Simatic Hmi Ktp Mobile Panels and 1 more | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
|
A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.
|
|||||
| CVE-2019-19244 | 4 Canonical, Oracle, Siemens and 1 more | 4 Ubuntu Linux, Mysql Workbench, Sinec Infrastructure Network Services and 1 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
|
sqlite3Select in select.c in SQLite 3.30.1 allows a crash if a sub-select uses both DISTINCT and window functions, and also has certain ORDER BY usage.
|
|||||
| CVE-2019-19242 | 5 Canonical, Oracle, Redhat and 2 more | 5 Ubuntu Linux, Mysql Workbench, Enterprise Linux and 2 more | 2024-11-21 | 4.3 MEDIUM | 5.9 MEDIUM |
|
SQLite 3.30.1 mishandles pExpr->y.pTab, as demonstrated by the TK_COLUMN case in sqlite3ExprCodeTarget in expr.c.
|
|||||
| CVE-2019-18342 | 1 Siemens | 1 Control Center Server | 2024-11-21 | 7.5 HIGH | 9.9 CRITICAL |
|
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server
(CCS) does not properly limit its capabilities to the specified purpose.
In conjunction with CVE-2019-18341, an unauthenticated remote attacker with
network access to the CCS server could exploit this vulnerability
to read or delete arbitrary files, or access other resources on the same
server.
|
|||||
| CVE-2019-18341 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
|
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server
(CCS) contains an authentication bypass vulnerability.
A remote attacker with network access to the CCS server could
exploit this vulnerability to read data from the EDIR directory
(for example, the list of all configured stations).
|
|||||
| CVE-2019-18340 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-11-21 | 2.1 LOW | 5.5 MEDIUM |
|
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0), Control Center Server (CCS) (All versions >= V1.5.0), SiNVR/SiVMS Video Server (All versions < V5.0.0), SiNVR/SiVMS Video Server (All versions >= V5.0.0). Both the SiVMS/SiNVR Video Server and the Control Center Server (CCS) store
user and device passwords by applying weak cryptography.
A local attacker could exploit this vulnerability to extract
the passwords from the user database and/or the device con ...
Show More |
|||||
| CVE-2019-18339 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The HTTP service (default port 5401/tcp) of the SiVMS/SiNVR Video Server
contains an authentication bypass vulnerability, even when properly
configured with enforced authentication.
A remote attacker with network access to the Video Server could
exploit this vulnerability to read the SiVMS/SiNVR users database, including
the passwords of all users in obfuscated cleartext.
|
|||||
| CVE-2019-18338 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-11-21 | 4.0 MEDIUM | 7.7 HIGH |
|
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains a directory traversal
vulnerability in its XML-based communication protocol as provided by default
on ports 5444/tcp and 5440/tcp.
An authenticated remote attacker with network access to the CCS server
could exploit this vulnerability to list arbitrary directories
or read files outside of the CCS application context.
|
|||||
| CVE-2019-18337 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-11-21 | 5.0 MEDIUM | 9.8 CRITICAL |
|
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an authentication bypass
vulnerability in its XML-based communication protocol as provided by default
on ports 5444/tcp and 5440/tcp.
A remote attacker with network access to the CCS server could
exploit this vulnerability to read the CCS users database, including
the passwords of all users in obfuscated cleartext.
|
|||||
| CVE-2019-18336 | 1 Siemens | 23 Simatic S7-300 Cpu, Simatic S7-300 Cpu 312 Ifm, Simatic S7-300 Cpu 312 Ifm Firmware and 20 more | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
|
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitati ...
Show More |
|||||
| CVE-2019-18335 | 1 Siemens | 1 Sppa-t3000 Application Server | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
|
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could be able to gain access to logs and configuration files by sending specifically crafted packets to 80/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was kno ...
Show More |
|||||
| CVE-2019-18334 | 1 Siemens | 1 Sppa-t3000 Application Server | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
|
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could be able to enumerate valid user names by sending specifically crafted packets to 8090/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
|
|||||
| CVE-2019-18333 | 1 Siemens | 1 Sppa-t3000 Application Server | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
|
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to filenames on the server by sending specifically crafted packets to 8090/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
|
|||||
| CVE-2019-18332 | 1 Siemens | 1 Sppa-t3000 Application Server | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
|
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to directory listings of the server by sending specifically crafted packets to 80/tcp, 8095/tcp or 8080/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulner ...
Show More |
|||||
| CVE-2019-18331 | 1 Siemens | 1 Sppa-t3000 Application Server | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
|
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to path and filenames on the server by sending specifically crafted packets to 1099/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
|
|||||
| CVE-2019-18330 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, and CVE-2019-18329. Please note that an attacker needs to have network access to the ...
Show More |
|||||
| CVE-2019-18329 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, and CVE-2019-18330. Please note that an attacker needs to have network access to the M ...
Show More |
|||||
| CVE-2019-18328 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the M ...
Show More |
|||||
| CVE-2019-18327 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the M ...
Show More |
|||||
| CVE-2019-18326 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18327, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the M ...
Show More |
|||||
| CVE-2019-18325 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the M ...
Show More |
|||||
| CVE-2019-18324 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the M ...
Show More |
|||||
| CVE-2019-18323 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
|
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the ...
Show More |
|||||