Vulnerabilities (CVE)

Filtered by vendor Rapid7
Angry Yack Logo
Total 75 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-35629 1 Rapid7 1 Velociraptor 2024-11-21 N/A 5.4 MEDIUM
Due to a bug in the handling of the communication between the client and server, it was possible for one client, already registered with their own client ID, to send messages to the server claiming to come from another client ID. This issue was resolved in Velociraptor 0.6.5-2.
CVE-2022-0758 1 Rapid7 1 Nexpose 2024-11-21 4.3 MEDIUM 3.3 LOW
Rapid7 Nexpose versions 6.6.129 and earlier suffer from a reflected cross site scripting vulnerability, within the shared scan configuration component of the tool. With this vulnerability an attacker could pass literal values as the test credentials, providing the opportunity for a potential XSS attack. This issue is fixed in Rapid7 Nexpose version 6.6.130.
CVE-2022-0757 1 Rapid7 1 Nexpose 2024-11-21 6.5 MEDIUM 5.5 MEDIUM
Rapid7 Nexpose versions 6.6.93 and earlier are susceptible to an SQL Injection vulnerability, whereby valid search operators are not defined. This lack of validation can allow a logged-in, authenticated attacker to manipulate the "ANY" and "OR" operators in the SearchCriteria and inject SQL code. This issue was fixed in Rapid7 Nexpose version 6.6.129.
CVE-2022-0237 1 Rapid7 1 Insight Agent 2024-11-21 7.2 HIGH 4.0 MEDIUM
Rapid7 Insight Agent versions 3.1.2.38 and earlier suffer from a privilege escalation vulnerability, whereby an attacker can hijack the flow of execution due to an unquoted argument to the runas.exe command used by the ir_agent.exe component, resulting in elevated rights and persistent access to the machine. This issue was fixed in Rapid7 Insight Agent version 3.1.3.80.
CVE-2021-4016 1 Rapid7 1 Insight Agent 2024-11-21 2.1 LOW 4.0 MEDIUM
Rapid7 Insight Agent, versions prior to 3.1.3, suffer from an improper access control vulnerability whereby, the user has access to the snapshot directory. An attacker can access, read and copy any of the files in this directory e.g. asset_info.json or file_info.json, leading to a loss of confidentiality. This issue was fixed in Rapid7 Insight Agent 3.1.3.
CVE-2021-4007 1 Rapid7 1 Insight Agent 2024-11-21 7.2 HIGH 7.8 HIGH
Rapid7 Insight Agent, versions 3.0.1 to 3.1.2.34, suffer from a local privilege escalation due to an uncontrolled DLL search path. Specifically, when Insight Agent versions 3.0.1 to 3.1.2.34 start, the Python interpreter attempts to load python3.dll at "C:\DLLs\python3.dll," which normally is writable by locally authenticated users. Because of this, a malicious local user could use Insight Agent's startup conditions to elevate to SYSTEM privileges. This issue was fixed in Rapid7 Insight Agent 3. ...

Show More

CVE-2021-3844 1 Rapid7 1 Insightvm 2024-11-21 N/A 5.7 MEDIUM
Rapid7 InsightVM suffers from insufficient session expiration when an administrator performs a security relevant edit on an existing, logged on user. For example, if a user's password is changed by an administrator due to an otherwise unrelated credential leak, that user account's current session is still valid after the password change, potentially allowing the attacker who originally compromised the credential to remain logged in and able to cause further damage. This vulnerability is mitigat ...

Show More

CVE-2021-3619 1 Rapid7 1 Velociraptor 2024-11-21 3.5 LOW 3.5 LOW
Rapid7 Velociraptor 0.5.9 and prior is vulnerable to a post-authentication persistent cross-site scripting (XSS) issue, where an authenticated user could abuse MIME filetype sniffing to embed executable code on a malicious upload. This issue was fixed in version 0.6.0. Note that login rights to Velociraptor is nearly always reserved for trusted and verified users with IT security backgrounds.
CVE-2021-3535 1 Rapid7 1 Nexpose 2024-11-21 4.3 MEDIUM 4.3 MEDIUM
Rapid7 Nexpose is vulnerable to a non-persistent cross-site scripting vulnerability affecting the Security Console's Filtered Asset Search feature. A specific search criterion and operator combination in Filtered Asset Search could have allowed a user to pass code through the provided search field. This issue affects version 6.6.80 and prior, and is fixed in 6.6.81. If your Security Console currently falls on or within this affected version range, ensure that you update your Security Console to ...

Show More

CVE-2021-31868 1 Rapid7 1 Nexpose 2024-11-21 5.5 MEDIUM 4.3 MEDIUM
Rapid7 Nexpose version 6.6.95 and earlier allows authenticated users of the Security Console to view and edit any ticket in the legacy ticketing feature, regardless of the assignment of the ticket. This issue was resolved in version 6.6.96, released on August 4, 2021.
CVE-2020-7385 1 Rapid7 1 Metasploit 2024-11-21 6.8 MEDIUM 8.1 HIGH
By launching the drb_remote_codeexec exploit, a Metasploit Framework user will inadvertently expose Metasploit to the same deserialization issue that is exploited by that module, due to the reliance on the vulnerable Distributed Ruby class functions. Since Metasploit Framework typically runs with elevated privileges, this can lead to a system compromise on the Metasploit workstation. Note that an attacker would have to lie in wait and entice the Metasploit user to run the affected module against ...

Show More

CVE-2020-7384 1 Rapid7 1 Metasploit 2024-11-21 9.3 HIGH 7.0 HIGH
Rapid7's Metasploit msfvenom framework handles APK files in a way that allows for a malicious user to craft and publish a file that would execute arbitrary commands on a victim's machine.
CVE-2020-7383 1 Rapid7 1 Nexpose 2024-11-21 5.5 MEDIUM 6.5 MEDIUM
A SQL Injection issue in Rapid7 Nexpose version prior to 6.6.49 that may have allowed an authenticated user with a low permission level to access resources & make changes they should not have been able to access.
CVE-2020-7382 1 Rapid7 1 Nexpose 2024-11-21 4.4 MEDIUM 6.8 MEDIUM
Rapid7 Nexpose installer version prior to 6.6.40 contains an Unquoted Search Path which may allow an attacker on the local machine to insert an arbitrary file into the executable path. This issue affects: Rapid7 Nexpose versions prior to 6.6.40.
CVE-2020-7381 1 Rapid7 1 Nexpose 2024-11-21 6.8 MEDIUM 5.8 MEDIUM
In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.
CVE-2020-7377 1 Rapid7 1 Metasploit 2024-11-21 5.0 MEDIUM 8.1 HIGH
The Metasploit Framework module "auxiliary/admin/http/telpho10_credential_dump" module is affected by a relative path traversal vulnerability in the untar method which can be exploited to write arbitrary files to arbitrary locations on the host file system when the module is run on a malicious HTTP server.
CVE-2020-7376 1 Rapid7 1 Metasploit 2024-11-21 10.0 HIGH 7.1 HIGH
The Metasploit Framework module "post/osx/gather/enum_osx module" is affected by a relative path traversal vulnerability in the get_keychains method which can be exploited to write arbitrary files to arbitrary locations on the host filesystem when the module is run on a malicious host.
CVE-2020-7358 1 Rapid7 1 Appspider 2024-11-21 4.4 MEDIUM 5.8 MEDIUM
In AppSpider installer versions prior to 7.2.126, the AppSpider installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during an installation and any arbitrary code executable using the same file name.
CVE-2020-7355 1 Rapid7 1 Metasploit 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
Cross-site Scripting (XSS) vulnerability in the 'notes' field of a discovered scan asset in Rapid7 Metasploit Pro allows an attacker with a specially-crafted network service of a scan target store an XSS sequence in the Metasploit Pro console, which will trigger when the operator views the record of that scanned host in the Metasploit Pro interface. This issue affects Rapid7 Metasploit Pro version 4.17.1-20200427 and prior versions, and is fixed in Metasploit Pro version 4.17.1-20200514. See als ...

Show More

CVE-2020-7354 1 Rapid7 1 Metasploit 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
Cross-site Scripting (XSS) vulnerability in the 'host' field of a discovered scan asset in Rapid7 Metasploit Pro allows an attacker with a specially-crafted network service of a scan target to store an XSS sequence in the Metasploit Pro console, which will trigger when the operator views the record of that scanned host in the Metasploit Pro interface. This issue affects Rapid7 Metasploit Pro version 4.17.1-20200427 and prior versions, and is fixed in Metasploit Pro version 4.17.1-20200514. See a ...

Show More

CVE-2020-7350 1 Rapid7 1 Metasploit 2024-11-21 6.8 MEDIUM 6.1 MEDIUM
Rapid7 Metasploit Framework versions before 5.0.85 suffers from an instance of CWE-78: OS Command Injection, wherein the libnotify plugin accepts untrusted user-supplied data via a remote computer's hostname or service name. An attacker can create a specially-crafted hostname or service name to be imported by Metasploit from a variety of sources and trigger a command injection on the operator's terminal. Note, only the Metasploit Framework and products that expose the plugin system is susceptibl ...

Show More

CVE-2019-5647 1 Rapid7 1 Appspider 2024-11-21 3.6 LOW 4.4 MEDIUM
The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215.
CVE-2019-5645 1 Rapid7 1 Metasploit 2024-11-21 5.0 MEDIUM 7.5 HIGH
By sending a specially crafted HTTP GET request to a listening Rapid7 Metasploit HTTP handler, an attacker can register an arbitrary regular expression. When evaluated, this malicious handler can either prevent new HTTP handler sessions from being established, or cause a resource exhaustion on the Metasploit server.
CVE-2019-5642 1 Rapid7 1 Metasploit 2024-11-21 2.1 LOW 3.3 LOW
Rapid7 Metasploit Pro version 4.16.0-2019081901 and prior suffers from an instance of CWE-732, wherein the unique server.key is written to the file system during installation with world-readable permissions. This can allow other users of the same system where Metasploit Pro is installed to intercept otherwise private communications to the Metasploit Pro web interface.
CVE-2019-5641 1 Rapid7 1 Insightvm 2024-11-21 N/A 3.3 LOW
Rapid7 InsightVM suffers from an information exposure issue whereby, when the user's session has ended due to inactivity, an attacker can use the Inspect Element browser feature to remove the login panel and view the details available in the last webpage visited by previous user
CVE-2019-5640 1 Rapid7 1 Nexpose 2024-11-21 5.0 MEDIUM 3.3 LOW
Rapid7 Nexpose versions prior to 6.6.114 suffer from an information exposure issue whereby, when the user's session has ended due to inactivity, an attacker can use the inspect element browser feature to remove the login panel and view the details available in the last webpage visited by previous user
CVE-2019-5638 1 Rapid7 1 Nexpose 2024-11-21 6.8 MEDIUM 8.7 HIGH
Rapid7 Nexpose versions 6.5.50 and prior suffer from insufficient session expiration when an administrator performs a security relevant edit on an existing, logged on user. For example, if a user's password is changed by an administrator due to an otherwise unrelated credential leak, that user account's current session is still valid after the password change, potentially allowing the attacker who originally compromised the credential to remain logged in and able to cause further damage.
CVE-2019-5631 1 Rapid7 1 Insightappsec 2024-11-21 9.3 HIGH 7.8 HIGH
The Rapid7 InsightAppSec broker suffers from a DLL injection vulnerability in the 'prunsrv.exe' component of the product. If exploited, a local user of the system (who must already be authenticated to the operating system) can elevate their privileges with this vulnerability to the privilege level of InsightAppSec (usually, SYSTEM). This issue affects version 2019.06.24 and prior versions of the product.
CVE-2019-5630 1 Rapid7 1 Nexpose 2024-11-21 6.8 MEDIUM 5.9 MEDIUM
A Cross-Site Request Forgery (CSRF) vulnerability was found in Rapid7 Nexpose InsightVM Security Console versions 6.5.0 through 6.5.68. This issue allows attackers to exploit CSRF vulnerabilities on API endpoints using Flash to circumvent a cross-domain pre-flight OPTIONS request.
CVE-2019-5629 1 Rapid7 1 Insight Agent 2024-11-21 7.2 HIGH 7.8 HIGH
Rapid7 Insight Agent, version 2.6.3 and prior, suffers from a local privilege escalation due to an uncontrolled DLL search path. Specifically, when Insight Agent 2.6.3 and prior starts, the Python interpreter attempts to load python3.dll at "C:\DLLs\python3.dll," which normally is writable by locally authenticated users. Because of this, a malicious local user could use Insight Agent's startup conditions to elevate to SYSTEM privileges. This issue was fixed in Rapid7 Insight Agent 2.6.4.
CVE-2019-5624 1 Rapid7 1 Metasploit 2024-11-21 6.5 MEDIUM 7.3 HIGH
Rapid7 Metasploit Framework suffers from an instance of CWE-22, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') in the Zip import function of Metasploit. Exploiting this vulnerability can allow an attacker to execute arbitrary code in Metasploit at the privilege level of the user running Metasploit. This issue affects: Rapid7 Metasploit Framework version 4.14.0 and prior versions.
CVE-2019-5615 1 Rapid7 1 Insightvm 2024-11-21 3.5 LOW 6.5 MEDIUM
Users with Site-level permissions can access files containing the username-encrypted passwords of Security Console Global Administrators and clear-text passwords for restoring backups, as well as the salt for those passwords. Valid credentials are required to access these files and malicious users would still need to perform additional work to decrypt the credentials and escalate privileges. This issue affects: Rapid7 InsightVM versions 6.5.11 through 6.5.49.
CVE-2018-5559 1 Rapid7 1 Komand 2024-11-21 4.0 MEDIUM 3.4 LOW
In Rapid7 Komand version 0.41.0 and prior, certain endpoints that are able to list the always encrypted-at-rest connection data could return some configurations of connection data without obscuring sensitive data from the API response sent over an encrypted channel. This issue does not affect Rapid7 Komand version 0.42.0 and later versions.
CVE-2012-6494 1 Rapid7 1 Nexpose 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
Rapid7 Nexpose before 5.5.4 contains a session hijacking vulnerability which allows remote attackers to capture a user's session and gain unauthorized access.
CVE-2024-8042 1 Rapid7 1 Insight Platform 2024-09-17 N/A 3.1 LOW
Rapid7 Insight Platform versions between November 2019 and August 14, 2024 suffer from missing authorization issues whereby an attacker can intercept local requests to set the name and description of a new user group. This could potentially lead to an empty user group being added to the incorrect customer. This vulnerability is remediated as of August 14, 2024.