Total
2901 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2024-2895 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way ...
Show More |
|||||
| CVE-2024-2896 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
|
|||||
| CVE-2024-2899 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did n ...
Show More |
|||||
| CVE-2024-2898 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in a ...
Show More |
|||||
| CVE-2024-2900 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure ...
Show More |
|||||
| CVE-2024-2901 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
|
|||||
| CVE-2024-2902 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way ...
Show More |
|||||
| CVE-2024-2891 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any w ...
Show More |
|||||
| CVE-2024-2581 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-22 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.
|
|||||
| CVE-2024-2903 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond i ...
Show More |
|||||
| CVE-2023-6749 | 1 Zephyrproject | 1 Zephyr | 2025-01-22 | N/A | 8.0 HIGH |
|
Unchecked length coming from user input in settings shell
|
|||||
| CVE-2024-31496 | 1 Fortinet | 3 Fortianalyzer, Fortianalyzer Big Data, Fortimanager | 2025-01-21 | N/A | 6.7 MEDIUM |
|
A stack-based buffer overflow vulnerability [CWE-121] in Fortinet FortiManager version 7.4.0 through 7.4.2 and before 7.2.5, FortiAnalyzer version 7.4.0 through 7.4.2 and before 7.2.5 and FortiAnalyzer-BigData 7.4.0 and before 7.2.7 allows a privileged attacker to execute unauthorized code or commands via crafted CLI requests.
|
|||||
| CVE-2020-12820 | 1 Fortinet | 1 Fortios | 2025-01-21 | N/A | 5.4 MEDIUM |
|
Under non-default configuration, a stack-based buffer overflow in FortiOS version 6.0.10 and below, version 5.6.12 and below may allow a remote attacker authenticated to the SSL VPN to crash the FortiClient NAC daemon (fcnacd) and potentially execute arbitrary code via requesting a large FortiClient file name. We are not aware of proof of concept code successfully achieving the latter.
|
|||||
| CVE-2024-4064 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond ...
Show More |
|||||
| CVE-2024-4065 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any ...
Show More |
|||||
| CVE-2024-4066 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclo ...
Show More |
|||||
| CVE-2024-3905 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not resp ...
Show More |
|||||
| CVE-2024-3906 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respon ...
Show More |
|||||
| CVE-2024-3910 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not res ...
Show More |
|||||
| CVE-2024-3875 | 1 Tenda | 2 F1202, F1202 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
|
|||||
| CVE-2024-3876 | 1 Tenda | 2 F1202, F1202 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
|
|||||
| CVE-2024-3877 | 1 Tenda | 2 F1202, F1202 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability classified as critical was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function fromqossetting of the file /goform/fromqossetting. The manipulation of the argument qos leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260911. NOTE: The vendor was contacted early about this disclosure but did not respond in any ...
Show More |
|||||
| CVE-2024-3878 | 1 Tenda | 2 F1202, F1202 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability, which was classified as critical, has been found in Tenda F1202 1.2.0.20(408). Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260912. NOTE: The vendor was contacted early about this disclosure but did not ...
Show More |
|||||
| CVE-2024-4166 | 1 Tenda | 2 4g300, 4g300 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability has been found in Tenda 4G300 1.01.42 and classified as critical. Affected by this vulnerability is the function sub_41E858. The manipulation of the argument GO/page leads to stack-based buffer overflow. The attack can be launched remotely. The identifier VDB-261985 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
|
|||||
| CVE-2024-4167 | 1 Tenda | 2 4g300, 4g300 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda 4G300 1.01.42 and classified as critical. Affected by this issue is the function sub_422AA4. The manipulation of the argument year/month/day/hour/minute/second leads to stack-based buffer overflow. The attack may be launched remotely. VDB-261986 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
|
|||||
| CVE-2024-4168 | 1 Tenda | 2 4g300, 4g300 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda 4G300 1.01.42. It has been classified as critical. This affects the function sub_4260F0. The manipulation of the argument upfilen leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-261987. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
|
|||||
| CVE-2024-4169 | 1 Tenda | 2 4g300, 4g300 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda 4G300 1.01.42. It has been declared as critical. This vulnerability affects the function sub_42775C/sub_4279CC. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-261988. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
|
|||||
| CVE-2024-4170 | 1 Tenda | 2 4g300, 4g300 Firmware | 2025-01-21 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
|
|||||
| CVE-2024-3907 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-01-17 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
|
|||||
| CVE-2025-21128 | 3 Adobe, Apple, Microsoft | 3 Substance 3d Stager, Macos, Windows | 2025-01-17 | N/A | 7.8 HIGH |
|
Substance3D - Stager versions 3.0.4 and earlier are affected by a Stack-based Buffer Overflow vulnerability that could result in arbitrary code execution in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file.
|
|||||
| CVE-2024-12803 | 2025-01-17 | N/A | 7.2 HIGH | ||
|
A post-authentication stack-based buffer overflow vulnerability in SonicOS management allows a remote attacker to crash a firewall and potentially leads to code execution.
|
|||||
| CVE-2024-34579 | 2025-01-17 | N/A | 7.8 HIGH | ||
|
Fuji Electric Alpha5 SMART
is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.
|
|||||
| CVE-2024-28928 | 1 Microsoft | 4 Sql Server 2016, Sql Server 2017, Sql Server 2019 and 1 more | 2025-01-15 | N/A | 8.8 HIGH |
|
SQL Server Native Client OLE DB Provider Remote Code Execution Vulnerability
|
|||||
| CVE-2024-29045 | 1 Microsoft | 3 Ole Db Driver For Sql Server, Sql Server 2019, Sql Server 2022 | 2025-01-15 | N/A | 7.5 HIGH |
|
Microsoft OLE DB Driver for SQL Server Remote Code Execution Vulnerability
|
|||||
| CVE-2024-4127 | 1 Tenda | 2 W15e, W15e Firmware | 2025-01-15 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. Affected is the function guestWifiRuleRefresh. The manipulation of the argument qosGuestDownstream leads to stack-based buffer overflow. It is possible to launch the attack remotely. VDB-261870 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
|
|||||
| CVE-2024-4126 | 1 Tenda | 2 W15e, W15e Firmware | 2025-01-15 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. This issue affects the function formSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument manualTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261869 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
|
|||||
| CVE-2024-4125 | 1 Tenda | 2 W15e, W15e Firmware | 2025-01-15 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. This vulnerability affects the function formSetStaticRoute of the file /goform/setStaticRoute. The manipulation of the argument staticRouteIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261868. NOTE: The vendor was contacted early about this disclosure but did not respond in ...
Show More |
|||||
| CVE-2024-4124 | 1 Tenda | 2 W15e, W15e Firmware | 2025-01-15 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. This affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261867. NOTE: The vendor was contacted early about this disclosure but did not ...
Show More |
|||||
| CVE-2024-4123 | 1 Tenda | 2 W15e, W15e Firmware | 2025-01-15 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability, which was classified as critical, has been found in Tenda W15E 15.11.0.14. Affected by this issue is the function formSetPortMapping of the file /goform/SetPortMapping. The manipulation of the argument portMappingServer/portMappingProtocol/portMappingWan/porMappingtInternal/portMappingExternal leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261866 is the identifier assigned to this vulne ...
Show More |
|||||
| CVE-2024-4122 | 1 Tenda | 2 W15e, W15e Firmware | 2025-01-15 | 9.0 HIGH | 8.8 HIGH |
|
A vulnerability classified as critical was found in Tenda W15E 15.11.0.14. Affected by this vulnerability is the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261865 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respon ...
Show More |
|||||