{"id": "CVE-2025-9362", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Secondary", "source": "
[email protected]", "cvssData": {"version": "2.0", "baseScore": 6.5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "authentication": "SINGLE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 6.4, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 8.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Secondary", "source": "
[email protected]", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 6.3, "attackVector": "NETWORK", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "integrityImpact": "LOW", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "LOW", "privilegesRequired": "LOW", "confidentialityImpact": "LOW"}, "impactScore": 3.4, "exploitabilityScore": 2.8}, {"type": "Primary", "source": "
[email protected]", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 8.8, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 2.8}], "cvssMetricV40": [{"type": "Secondary", "source": "
[email protected]", "cvssData": {"Safety": "NOT_DEFINED", "version": "4.0", "Recovery": "NOT_DEFINED", "baseScore": 5.3, "Automatable": "NOT_DEFINED", "attackVector": "NETWORK", "baseSeverity": "MEDIUM", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "exploitMaturity": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "userInteraction": "NONE", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "LOW", "subIntegrityImpact": "NONE", "vulnIntegrityImpact": "LOW", "integrityRequirement": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "vulnAvailabilityImpact": "LOW", "availabilityRequirement": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "subConfidentialityImpact": "NONE", "vulnConfidentialityImpact": "LOW", "confidentialityRequirement": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED"}}]}, "published": "2025-08-23T14:15:31.473", "references": [{"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_30/30.md", "tags": ["Exploit", "Third Party Advisory"], "source": "
[email protected]"}, {"url": "https://vuldb.com/?ctiid.321065", "tags": ["Permissions Required"], "source": "
[email protected]"}, {"url": "https://vuldb.com/?id.321065", "tags": ["Third Party Advisory", "VDB Entry"], "source": "
[email protected]"}, {"url": "https://vuldb.com/?submit.631534", "tags": ["Third Party Advisory", "VDB Entry"], "source": "
[email protected]"}, {"url": "https://www.linksys.com/", "tags": ["Product"], "source": "
[email protected]"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "
[email protected]", "description": [{"lang": "en", "value": "CWE-119"}, {"lang": "en", "value": "CWE-121"}]}], "descriptions": [{"lang": "en", "value": "A flaw has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. The impacted element is the function urlFilterManageRule of the file /goform/urlFilterManageRule. Executing manipulation of the argument urlFilterRuleName/scheduleUrl/addURLFilter can lead to stack-based buffer overflow. The attack may be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way."}, {"lang": "es", "value": "Se ha detectado una falla en los Linksys RE6250, RE6300, RE6350, RE6500, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. El elemento afectado es la funci\u00f3n urlFilterManageRule del archivo /goform/urlFilterManageRule. La manipulaci\u00f3n del argumento urlFilterRuleName/scheduleUrl/addURLFilter puede provocar un desbordamiento del b\u00fafer basado en la pila. El ataque puede ejecutarse en remoto. Se contact\u00f3 al proveedor con antelaci\u00f3n para informarle sobre esta revelaci\u00f3n, pero no respondi\u00f3."}], "lastModified": "2025-09-02T18:18:50.370", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "
[email protected]"}