{"id": "CVE-2025-9358", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Secondary", "source": "
[email protected]", "cvssData": {"version": "2.0", "baseScore": 9.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "authentication": "SINGLE", "integrityImpact": "COMPLETE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}, "acInsufInfo": false, "impactScore": 10.0, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 8.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "
[email protected]", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 8.8, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 2.8}], "cvssMetricV40": [{"type": "Secondary", "source": "
[email protected]", "cvssData": {"Safety": "NOT_DEFINED", "version": "4.0", "Recovery": "NOT_DEFINED", "baseScore": 7.4, "Automatable": "NOT_DEFINED", "attackVector": "NETWORK", "baseSeverity": "HIGH", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "exploitMaturity": "PROOF_OF_CONCEPT", "providerUrgency": "NOT_DEFINED", "userInteraction": "NONE", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "LOW", "subIntegrityImpact": "NONE", "vulnIntegrityImpact": "HIGH", "integrityRequirement": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "vulnAvailabilityImpact": "HIGH", "availabilityRequirement": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "subConfidentialityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED"}}]}, "published": "2025-08-23T08:15:29.837", "references": [{"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_26/26.md", "tags": ["Exploit", "Third Party Advisory"], "source": "
[email protected]"}, {"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_26/26.md#poc", "tags": ["Exploit", "Third Party Advisory"], "source": "
[email protected]"}, {"url": "https://vuldb.com/?ctiid.321061", "tags": ["Permissions Required"], "source": "
[email protected]"}, {"url": "https://vuldb.com/?id.321061", "tags": ["Third Party Advisory", "VDB Entry"], "source": "
[email protected]"}, {"url": "https://vuldb.com/?submit.631530", "tags": ["Third Party Advisory", "VDB Entry"], "source": "
[email protected]"}, {"url": "https://www.linksys.com/", "tags": ["Product"], "source": "
[email protected]"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "
[email protected]", "description": [{"lang": "en", "value": "CWE-119"}, {"lang": "en", "value": "CWE-121"}]}], "descriptions": [{"lang": "en", "value": "A security flaw has been discovered in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function setSysAdm of the file /goform/setSysAdm. The manipulation of the argument admpasshint results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way."}, {"lang": "es", "value": "Se ha descubierto una falla de seguridad en los Linksys RE6250, RE6300, RE6350, RE6500, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esta vulnerabilidad afecta a la funci\u00f3n setSysAdm del archivo /goform/setSysAdm. La manipulaci\u00f3n del argumento admpasshint provoca un desbordamiento del b\u00fafer basado en la pila. Es posible ejecutar el ataque de forma remota. Se ha hecho p\u00fablico el exploit y puede que sea utilizado. Se contact\u00f3 al proveedor con antelaci\u00f3n para informarle sobre esta divulgaci\u00f3n, pero no respondi\u00f3."}], "lastModified": "2025-09-02T18:19:21.077", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "
[email protected]"}