{"id": "CVE-2025-9250", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Secondary", "source": "
[email protected]", "cvssData": {"version": "2.0", "baseScore": 9.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "authentication": "SINGLE", "integrityImpact": "COMPLETE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}, "acInsufInfo": false, "impactScore": 10.0, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 8.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Secondary", "source": "
[email protected]", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 8.8, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 2.8}], "cvssMetricV40": [{"type": "Secondary", "source": "
[email protected]", "cvssData": {"Safety": "NOT_DEFINED", "version": "4.0", "Recovery": "NOT_DEFINED", "baseScore": 7.4, "Automatable": "NOT_DEFINED", "attackVector": "NETWORK", "baseSeverity": "HIGH", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "exploitMaturity": "PROOF_OF_CONCEPT", "providerUrgency": "NOT_DEFINED", "userInteraction": "NONE", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "LOW", "subIntegrityImpact": "NONE", "vulnIntegrityImpact": "HIGH", "integrityRequirement": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "vulnAvailabilityImpact": "HIGH", "availabilityRequirement": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "subConfidentialityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED"}}]}, "published": "2025-08-20T22:15:29.850", "references": [{"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_19/19.md", "tags": ["Exploit", "Third Party Advisory"], "source": "
[email protected]"}, {"url": "https://vuldb.com/?ctiid.320781", "tags": ["Permissions Required"], "source": "
[email protected]"}, {"url": "https://vuldb.com/?id.320781", "tags": ["Third Party Advisory", "VDB Entry"], "source": "
[email protected]"}, {"url": "https://vuldb.com/?submit.631523", "tags": ["Third Party Advisory", "VDB Entry"], "source": "
[email protected]"}, {"url": "https://www.linksys.com/", "tags": ["Product"], "source": "
[email protected]"}, {"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_19/19.md", "tags": ["Exploit", "Third Party Advisory"], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Secondary", "source": "
[email protected]", "description": [{"lang": "en", "value": "CWE-119"}, {"lang": "en", "value": "CWE-121"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This impacts the function setPWDbyBBS of the file /goform/setPWDbyBBS. Such manipulation of the argument hint leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way."}, {"lang": "es", "value": "Se identific\u00f3 una vulnerabilidad en Linksys RE6250, RE6300, RE6350, RE6500, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esta vulnerabilidad afecta a la funci\u00f3n setPWDbyBBS del archivo /goform/setPWDbyBBS. Esta manipulaci\u00f3n de la sugerencia del argumento provoca un desbordamiento del b\u00fafer en la pila. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado. Se contact\u00f3 al proveedor con antelaci\u00f3n para informarle sobre esta divulgaci\u00f3n, pero no respondi\u00f3."}], "lastModified": "2025-09-02T18:23:17.187", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "
[email protected]"}