{"id": "CVE-2025-9248", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Secondary", "source": "
[email protected]", "cvssData": {"version": "2.0", "baseScore": 9.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "authentication": "SINGLE", "integrityImpact": "COMPLETE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}, "acInsufInfo": false, "impactScore": 10.0, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 8.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Secondary", "source": "
[email protected]", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 8.8, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 2.8}], "cvssMetricV40": [{"type": "Secondary", "source": "
[email protected]", "cvssData": {"Safety": "NOT_DEFINED", "version": "4.0", "Recovery": "NOT_DEFINED", "baseScore": 7.4, "Automatable": "NOT_DEFINED", "attackVector": "NETWORK", "baseSeverity": "HIGH", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "exploitMaturity": "PROOF_OF_CONCEPT", "providerUrgency": "NOT_DEFINED", "userInteraction": "NONE", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "LOW", "subIntegrityImpact": "NONE", "vulnIntegrityImpact": "HIGH", "integrityRequirement": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "vulnAvailabilityImpact": "HIGH", "availabilityRequirement": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "subConfidentialityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED"}}]}, "published": "2025-08-20T21:15:32.630", "references": [{"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_17/17.md", "tags": ["Exploit", "Third Party Advisory"], "source": "
[email protected]"}, {"url": "https://vuldb.com/?ctiid.320779", "tags": ["Permissions Required"], "source": "
[email protected]"}, {"url": "https://vuldb.com/?id.320779", "tags": ["Third Party Advisory", "VDB Entry"], "source": "
[email protected]"}, {"url": "https://vuldb.com/?submit.631521", "tags": ["Third Party Advisory", "VDB Entry"], "source": "
[email protected]"}, {"url": "https://www.linksys.com/", "tags": ["Product"], "source": "
[email protected]"}, {"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_17/17.md", "tags": ["Exploit", "Third Party Advisory"], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Secondary", "source": "
[email protected]", "description": [{"lang": "en", "value": "CWE-119"}, {"lang": "en", "value": "CWE-121"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. The impacted element is the function RP_pingGatewayByBBS of the file /goform/RP_pingGatewayByBBS. The manipulation of the argument ssidhex results in stack-based buffer overflow. The attack may be performed from a remote location. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way."}, {"lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Linksys RE6250, RE6300, RE6350, RE6500, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. El elemento afectado es la funci\u00f3n RP_pingGatewayByBBS del archivo /goform/RP_pingGatewayByBBS. La manipulaci\u00f3n del argumento ssidhex provoca un desbordamiento del b\u00fafer basado en la pila. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado. Se contact\u00f3 al proveedor con antelaci\u00f3n para informarle sobre esta divulgaci\u00f3n, pero no respondi\u00f3."}], "lastModified": "2025-09-02T18:22:42.417", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "
[email protected]"}