{"id": "CVE-2025-9247", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Secondary", "source": "
[email protected]", "cvssData": {"version": "2.0", "baseScore": 9.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "authentication": "SINGLE", "integrityImpact": "COMPLETE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}, "acInsufInfo": false, "impactScore": 10.0, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 8.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Secondary", "source": "
[email protected]", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 8.8, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 2.8}], "cvssMetricV40": [{"type": "Secondary", "source": "
[email protected]", "cvssData": {"Safety": "NOT_DEFINED", "version": "4.0", "Recovery": "NOT_DEFINED", "baseScore": 7.4, "Automatable": "NOT_DEFINED", "attackVector": "NETWORK", "baseSeverity": "HIGH", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "exploitMaturity": "PROOF_OF_CONCEPT", "providerUrgency": "NOT_DEFINED", "userInteraction": "NONE", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "LOW", "subIntegrityImpact": "NONE", "vulnIntegrityImpact": "HIGH", "integrityRequirement": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "vulnAvailabilityImpact": "HIGH", "availabilityRequirement": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "subConfidentialityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED"}}]}, "published": "2025-08-20T21:15:32.393", "references": [{"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_16/16.md", "tags": ["Exploit", "Third Party Advisory"], "source": "
[email protected]"}, {"url": "https://vuldb.com/?ctiid.320778", "tags": ["Permissions Required"], "source": "
[email protected]"}, {"url": "https://vuldb.com/?id.320778", "tags": ["Third Party Advisory", "VDB Entry"], "source": "
[email protected]"}, {"url": "https://vuldb.com/?submit.631520", "tags": ["Third Party Advisory", "VDB Entry"], "source": "
[email protected]"}, {"url": "https://www.linksys.com/", "tags": ["Product"], "source": "
[email protected]"}, {"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_16/16.md", "tags": ["Exploit", "Third Party Advisory"], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Secondary", "source": "
[email protected]", "description": [{"lang": "en", "value": "CWE-119"}, {"lang": "en", "value": "CWE-121"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. The affected element is the function setVlan of the file /goform/setVlan. The manipulation of the argument vlan_set leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."}, {"lang": "es", "value": "Se ha detectado una vulnerabilidad en los Linksys RE6250, RE6300, RE6350, RE6500, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. El elemento afectado es la funci\u00f3n setVlan del archivo /goform/setVlan. La manipulaci\u00f3n del argumento vlan_set provoca un desbordamiento del b\u00fafer basado en la pila. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado. Se contact\u00f3 al proveedor con antelaci\u00f3n para informarle sobre esta divulgaci\u00f3n, pero no respondi\u00f3."}], "lastModified": "2025-09-02T18:22:35.500", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "
[email protected]"}