CVE-2024-4639

O

nCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands.

Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:moxa:oncell_g3470a-lte-us-t_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:moxa:oncell_g3470a-lte-us-t:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:moxa:oncell_g3470a-lte-eu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:moxa:oncell_g3470a-lte-eu:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:moxa:oncell_g3470a-lte-eu-t_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:moxa:oncell_g3470a-lte-eu-t:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:moxa:oncell_g3470a-lte-us_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:moxa:oncell_g3470a-lte-us:-:*:*:*:*:*:*:*

History

21 Nov 2024, 09:43

Type Values Removed Values Added
References () https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities - Vendor Advisory () https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities - Vendor Advisory
CVSS v2 : unknown
v3 : 8.8
v2 : unknown
v3 : 7.1

18 Sep 2024, 15:46

Type Values Removed Values Added
References () https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities - () https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities - Vendor Advisory
CVSS v2 : unknown
v3 : 7.1
v2 : unknown
v3 : 8.8
CPE cpe:2.3:h:moxa:oncell_g3470a-lte-eu-t:-:*:*:*:*:*:*:*
cpe:2.3:o:moxa:oncell_g3470a-lte-us_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:moxa:oncell_g3470a-lte-us:-:*:*:*:*:*:*:*
cpe:2.3:o:moxa:oncell_g3470a-lte-eu-t_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:moxa:oncell_g3470a-lte-eu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:moxa:oncell_g3470a-lte-us-t_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:moxa:oncell_g3470a-lte-us-t:-:*:*:*:*:*:*:*
cpe:2.3:h:moxa:oncell_g3470a-lte-eu:-:*:*:*:*:*:*:*
First Time Moxa oncell G3470a-lte-us-t Firmware
Moxa oncell G3470a-lte-eu
Moxa oncell G3470a-lte-eu-t Firmware
Moxa
Moxa oncell G3470a-lte-us
Moxa oncell G3470a-lte-us-t
Moxa oncell G3470a-lte-eu-t
Moxa oncell G3470a-lte-eu Firmware
Moxa oncell G3470a-lte-us Firmware

25 Jun 2024, 12:24

Type Values Removed Values Added
Summary
  • (es) Las versiones de firmware de la serie OnCell G3470A-LTE v1.7.7 y anteriores han sido identificadas como vulnerables debido a la falta de entradas neutralizadas en la configuración IPSec. Un atacante podría modificar los comandos previstos enviados a las funciones de destino, lo que podría provocar que usuarios malintencionados ejecuten comandos no autorizados.

25 Jun 2024, 10:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-06-25 10:15

Updated : 2025-03-10 20:07


NVD link : CVE-2024-4639

Mitre link : CVE-2024-4639

CVE.ORG link : CVE-2024-4639


JSON object : View

CWE
CWE-77

Improper Neutralization of Special Elements used in a Command ('Command Injection')