CVE-2024-45272

A

n unauthenticated remote attacker can perform a brute-force attack on the credentials of the remote service portal with a high chance of success, resulting in connection lost.

Configurations

Configuration 1 (hide)

cpe:2.3:a:helmholz:myrex24_v2_virtual_server:*:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:helmholz:rex_300_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:helmholz:rex_300:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:helmholz:rex_200_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:helmholz:rex_250_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:helmholz:rex_250:-:*:*:*:*:*:*:*

Configuration 5 (hide)

OR cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*
cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:mbconnectline:mbspider_mdh_905_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mbconnectline:mbspider_mdh_905:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:mbconnectline:mbspider_mdh_915_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mbconnectline:mbspider_mdh_915:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:mbconnectline:mbspider_mdh_906_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mbconnectline:mbspider_mdh_906:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:mbconnectline:mbspider_mdh_916_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mbconnectline:mbspider_mdh_916:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:mbconnectline:mbnet_hw1_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mbconnectline:mbnet_hw1:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:mbconnectline:mbnet_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mbconnectline:mbnet:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:mbconnectline:mbnet.rokey_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mbconnectline:mbnet.rokey:-:*:*:*:*:*:*:*

History

21 Nov 2024, 09:37

Type Values Removed Values Added
References
  • () https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-061.txt -

17 Oct 2024, 17:42

Type Values Removed Values Added
CPE cpe:2.3:o:helmholz:rex_200_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mbconnectline:mbspider_mdh_915_firmware:*:*:*:*:*:*:*:*
cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*
cpe:2.3:o:mbconnectline:mbspider_mdh_906_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mbconnectline:mbspider_mdh_916_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mbconnectline:mbspider_mdh_905_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mbconnectline:mbspider_mdh_916:-:*:*:*:*:*:*:*
cpe:2.3:o:helmholz:rex_300_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:helmholz:rex_250:-:*:*:*:*:*:*:*
cpe:2.3:h:mbconnectline:mbnet:-:*:*:*:*:*:*:*
cpe:2.3:h:helmholz:rex_300:-:*:*:*:*:*:*:*
cpe:2.3:h:mbconnectline:mbnet.rokey:-:*:*:*:*:*:*:*
cpe:2.3:h:mbconnectline:mbspider_mdh_915:-:*:*:*:*:*:*:*
cpe:2.3:o:mbconnectline:mbnet.rokey_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*
cpe:2.3:h:mbconnectline:mbspider_mdh_906:-:*:*:*:*:*:*:*
cpe:2.3:h:mbconnectline:mbnet_hw1:-:*:*:*:*:*:*:*
cpe:2.3:o:mbconnectline:mbnet_firmware:*:*:*:*:*:*:*:*
cpe:2.3:a:helmholz:myrex24_v2_virtual_server:*:*:*:*:*:*:*:*
cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*
cpe:2.3:o:mbconnectline:mbnet_hw1_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:helmholz:rex_250_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:mbconnectline:mbspider_mdh_905:-:*:*:*:*:*:*:*
References () https://cert.vde.com/en/advisories/VDE-2024-068 - () https://cert.vde.com/en/advisories/VDE-2024-068 - Third Party Advisory
References () https://cert.vde.com/en/advisories/VDE-2024-069 - () https://cert.vde.com/en/advisories/VDE-2024-069 - Third Party Advisory
First Time Helmholz rex 300
Mbconnectline mbspider Mdh 905 Firmware
Mbconnectline
Mbconnectline mbspider Mdh 916
Helmholz myrex24 V2 Virtual Server
Mbconnectline mbnet Firmware
Mbconnectline mbspider Mdh 905
Helmholz rex 300 Firmware
Mbconnectline mbnet Hw1 Firmware
Mbconnectline mbspider Mdh 916 Firmware
Mbconnectline mbspider Mdh 915 Firmware
Helmholz rex 250 Firmware
Mbconnectline mbspider Mdh 906 Firmware
Helmholz rex 200 Firmware
Helmholz rex 200
Mbconnectline mbnet.rokey Firmware
Mbconnectline mbspider Mdh 906
Mbconnectline mbspider Mdh 915
Mbconnectline mbnet Hw1
Helmholz rex 250
Mbconnectline mymbconnect24
Mbconnectline mbnet
Mbconnectline mbconnect24
Mbconnectline mbnet.rokey
Helmholz
CWE NVD-CWE-Other
Summary
  • (es) Un atacante remoto no autenticado puede realizar un ataque de fuerza bruta a las credenciales del portal de servicio remoto con una alta probabilidad de éxito, lo que da como resultado la pérdida de la conexión.

15 Oct 2024, 11:15

Type Values Removed Values Added
New CVE