iX toolset lets developers create installers for Windows Installer, the Windows installation engine. The custom action behind WiX's `RemoveFolderEx` functionality could allow a standard user to delete protected directories. `RemoveFolderEx` deletes an entire directory tree during installation or uninstallation. It does so by recursing every subdirectory starting at a specified directory and adding each subdirectory to the list of directories Windows Installer should delete. If the setup author instructed `RemoveFolderEx` to delete a per-user folder from a per-machine installer, an attacker could create a directory junction in that per-user folder pointing to a per-machine, protected directory. Windows Installer, when executing the per-machine installer after approval by an administrator, would delete the target of the directory junction. This vulnerability is fixed in 3.14.1 and 4.0.5.
No configuration.
21 Nov 2024, 09:07
| Type | Values Removed | Values Added |
|---|---|---|
| References | () https://github.com/wixtoolset/issues/security/advisories/GHSA-jx4p-m4wm-vvjg - | |
| References | () https://github.com/wixtoolset/wix/commit/2e5960b575881567a8807e6b8b9c513138b19742 - | |
| References | () https://github.com/wixtoolset/wix3/commit/93eeb5f6835776694021f66d4226c262c67d487a - |
Published : 2024-03-24 20:15
Updated : 2024-11-21 09:07
NVD link : CVE-2024-29188
Mitre link : CVE-2024-29188
CVE.ORG link : CVE-2024-29188
JSON object : View
No product.
Improper Link Resolution Before File Access ('Link Following')