{"id": "CVE-2023-40069", "metrics": {"cvssMetricV31": [{"type": "Primary", "source": "
[email protected]", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}, {"type": "Secondary", "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}]}, "published": "2023-08-18T10:15:12.653", "references": [{"url": "https://jvn.jp/en/vu/JVNVU91630351/", "tags": ["Third Party Advisory"], "source": "
[email protected]"}, {"url": "https://www.elecom.co.jp/news/security/20230810-01/", "tags": ["Vendor Advisory"], "source": "
[email protected]"}, {"url": "https://jvn.jp/en/vu/JVNVU91630351/", "tags": ["Third Party Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "https://www.elecom.co.jp/news/security/20230810-01/", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "
[email protected]", "description": [{"lang": "en", "value": "CWE-78"}]}, {"type": "Secondary", "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "description": [{"lang": "en", "value": "CWE-78"}]}], "descriptions": [{"lang": "en", "value": "OS command injection vulnerability in ELECOM wireless LAN routers allows an attacker who can access the product to execute an arbitrary OS command by sending a specially crafted request. Affected products and versions are as follows: WRC-F1167ACF all versions, WRC-1750GHBK all versions, WRC-1167GHBK2 all versions, WRC-1750GHBK2-I all versions, and WRC-1750GHBK-E all versions."}, {"lang": "es", "value": "La vulnerabilidad de inyecci\u00f3n de comandos del sistema operativo en los routers LAN inal\u00e1mbricos ELECOM permite a un atacante que pueda acceder al producto ejecutar un comando arbitrario del sistema operativo enviando una solicitud especialmente dise\u00f1ada. Los productos y versiones afectados son los siguientes WRC-F1167ACF todas las versiones, WRC-1750GHBK todas las versiones, WRC-1167GHBK2 todas las versiones, WRC-1750GHBK2-I todas las versiones y WRC-1750GHBK-E todas las versiones.\n"}], "lastModified": "2024-11-21T08:18:38.257", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:elecom:wrc-f1167acf_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0233A6C1-4F74-4347-B204-899F0504E713"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:elecom:wrc-f1167acf:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "C244EA13-D45C-4968-A330-3AD80F588537"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:elecom:wrc-1750ghbk_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E00CABDD-B213-4DAA-9FC4-D907AC465134"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:elecom:wrc-1750ghbk:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "5D1F1675-60C1-4150-8306-1592F88D3DAC"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:elecom:wrc-1167ghbk2_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "07F1B061-C150-4DED-B3DE-B6DDB67AF1C4"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:elecom:wrc-1167ghbk2:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "7DF1D75E-EF09-4BF7-AC5C-F6CDC5B6ED8E"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:elecom:wrc-1750ghbk2-i_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "491E938A-060D-4A3E-B466-F2BC12DEF9F1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:elecom:wrc-1750ghbk2-i:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "E1EAF366-E7EB-4864-BB1C-16D828141CFD"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:elecom:wrc-1750ghbk-e_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "680D6E21-6065-4FCA-A8E6-DF53BD2E4927"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:elecom:wrc-1750ghbk-e:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "DDB8292C-ABDA-4F61-8EF1-D498AE3BF66C"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "
[email protected]"}