{"id": "CVE-2022-46670", "metrics": {"cvssMetricV31": [{"type": "Secondary", "source": "
[email protected]", "cvssData": {"scope": "CHANGED", "version": "3.1", "baseScore": 7.1, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L", "integrityImpact": "LOW", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "LOW", "privilegesRequired": "NONE", "confidentialityImpact": "LOW"}, "impactScore": 3.7, "exploitabilityScore": 2.8}, {"type": "Primary", "source": "
[email protected]", "cvssData": {"scope": "CHANGED", "version": "3.1", "baseScore": 6.1, "attackVector": "NETWORK", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "integrityImpact": "LOW", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "LOW"}, "impactScore": 2.7, "exploitabilityScore": 2.8}]}, "published": "2022-12-16T21:15:09.040", "references": [{"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679", "tags": ["Vendor Advisory"], "source": "
[email protected]"}, {"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "
[email protected]", "description": [{"lang": "en", "value": "CWE-79"}]}, {"type": "Primary", "source": "
[email protected]", "description": [{"lang": "en", "value": "CWE-79"}]}], "descriptions": [{"lang": "en", "value": "\nRockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute\u00a0of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. \u00a0The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. \n\n"}, {"lang": "es", "value": "Un investigador de seguridad del Instituto de Tecnolog\u00eda de Georgia inform\u00f3 a Rockwell Automation de una vulnerabilidad que indica que los controladores MicroLogix 1100 y 1400 contienen una vulnerabilidad que puede brindarle a un atacante la capacidad de realizar la ejecuci\u00f3n remota de c\u00f3digo. La vulnerabilidad es de Cross-Site Scripting almacenado, no autenticada en el servidor web integrado. El payload se transfiere al controlador a trav\u00e9s de SNMP y se representa en la p\u00e1gina de inicio del sitio web integrado."}], "lastModified": "2024-11-21T07:30:52.580", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:rockwellautomation:micrologix_1400_firmware:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "11507EFF-5C53-4217-9257-21936118C032"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:rockwellautomation:micrologix_1400:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "196EA0BE-FDF3-46BE-B3DA-5F49208C5D80"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:rockwellautomation:micrologix_1100_firmware:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "DCE86CDF-12CC-4B02-942D-BF9134218F2B"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:rockwellautomation:micrologix_1100:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "DA42C7F4-EEC1-44D2-BD46-237969FF6E1A"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:rockwellautomation:micrologix_1400-b_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E6C4D215-CB09-4BEA-89A6-2BAACD461FBE", "versionEndIncluding": "21.007"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:rockwellautomation:micrologix_1400-b:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "3D01BD0A-CA96-4882-8523-EC4D522DA4AF"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:rockwellautomation:micrologix_1400-c_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "FD745E1D-10D9-4FD6-9F7C-63CB51F3C454", "versionEndIncluding": "21.007"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:rockwellautomation:micrologix_1400-c:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "DC9A2DE5-E745-4F1B-931C-E11814A7D23A"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:rockwellautomation:micrologix_1400-a_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2E2B3E77-CF64-4D7F-A849-5462CABB576D", "versionEndIncluding": "7.000"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:rockwellautomation:micrologix_1400-a:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "81AFED05-B927-4BF7-ABC5-5E3F7555593D"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "
[email protected]"}