{"id": "CVE-2022-46351", "cveTags": [], "metrics": {"cvssMetricV31": [{"type": "Primary", "source": "
[email protected]", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 5.5, "attackVector": "LOCAL", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 1.8}, {"type": "Secondary", "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 5.5, "attackVector": "LOCAL", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 1.8}]}, "published": "2022-12-13T16:15:25.730", "references": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363821.pdf", "tags": ["Patch", "Vendor Advisory"], "source": "
[email protected]"}, {"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363821.pdf", "tags": ["Patch", "Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "
[email protected]", "description": [{"lang": "en", "value": "CWE-400"}]}, {"type": "Primary", "source": "
[email protected]", "description": [{"lang": "en", "value": "CWE-400"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). Specially crafted PROFINET DCP packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2)."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en:\nSCALANCE X204RNA (HSR) (Todas las versiones < V3.2.7), \nSCALANCE X204RNA (PRP) (Todas las versiones < V3.2.7), \nSCALANCE X204RNA EEC (HSR) (Todas las versiones < V3.2.7 ), \nSCALANCE X204RNA EEC (PRP) (todas las versiones < V3.2.7), \nSCALANCE X204RNA EEC (PRP/HSR) (todas las versiones < V3.2.7). \nLos paquetes PROFINET DCP especialmente manipulados podr\u00edan provocar una condici\u00f3n de Denegaci\u00f3n de Servicio (DoS) de los productos afectados en un segmento Ethernet local (Capa 2)."}], "lastModified": "2025-04-22T03:15:20.190", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:6gk5204-0ba00-2mb2_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "77A54E43-E9A5-49CF-BA3C-E6878C2C713F", "versionEndExcluding": "3.2.7"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:6gk5204-0ba00-2mb2:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "AF6E5E68-552D-40C1-A4AB-605D0F21688F"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:6gk5204-0ba00-2kb2_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "CE326B9F-A613-46B5-A20D-BE9D41A80857", "versionEndExcluding": "3.2.7"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:6gk5204-0ba00-2kb2:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "7B61CA05-D98E-4BD6-BE78-58574B2DE5CA"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:6gk5204-0bs00-2na3_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F6FCF31E-22CA-4038-AC27-BAEA752A718D", "versionEndExcluding": "3.2.7"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:6gk5204-0bs00-2na3:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "28B98E8F-0E32-4BA4-8237-055BDB25C1B3"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:6gk5204-0bs00-3la3_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A7EA94F5-1AB0-4BE2-810A-46B840070856", "versionEndExcluding": "3.2.7"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:6gk5204-0bs00-3la3:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "D92CFF31-E138-49D0-A9FF-A91E7342AEFC"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:6gk5204-0bs00-3pa3_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "06CBD11B-3671-425B-89EB-4B9677B3316B", "versionEndExcluding": "3.2.7"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:6gk5204-0bs00-3pa3:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "1572F77B-98B7-44D9-9DF9-9EC56CD6E571"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "
[email protected]"}